Nordson_EFD_GV_Series_Operating_Manual.pdf - 第7页
GV Series Automated Dispensing Systems 7 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide. Nor dson EFD Pr oduct Safety Statement The safe…

GV Series Automated Dispensing Systems
6 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Introduction
This manual provides installation, setup, programming, operation, and service information for all components of a
Nordson EFD GV Series automated dispensing system. Nordson EFD’s automated dispensing systems dispense
fluid in a preprogrammed pattern onto a workpiece. They are specifically designed and configured for use with
Nordson EFD industrial syringe barrel and valve systems. Automated dispensing systems offer the flexibility of
working either as a stand-alone system or as a key part of an automated solution and are easily integrated into in-
line transfer systems, rotary tables, and pallet assembly lines.
The primary components of an automated dispensing system are the DispenseMotion
™
controller, the robot, and the
dispensing system components. The robot executes a computer program to dispense fluid in a specific pattern onto
a workpiece. Programs are created using the DispenseMotion software installed on the DispenseMotion controller.
The dispensing system may be contact or non-contact, with material being dispensed through either a dispensing
tip or nozzle. For the purposes of this manual, “dispensing tip” refers to either a tip or a nozzle.
Using the precision-vision camera, the robot can automatically adjust the dispense program for each workpiece,
allowing for variations in the workpiece position or orientation. To accomplish this, the software compares the
current workpiece location to within ±2.5 mm (0.098") of a reference location that is stored as an image file (called
a mark file) in the program. If the robot detects a difference in the X and Y positions and / or the angle of rotation of
the workpiece, it adjusts the dispensing path to correct for the difference.

GV Series Automated Dispensing Systems
7www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Nordson EFD Product Safety Statement
The safety messages that follow have a CAUTION level hazard.
Failure to comply may result in minor or moderate injury.
CAUTION
READ MANUAL
Read manual for proper use of this equipment. Follow all safety instructions. Task- and equipment-
specific warnings, cautions, and instructions are included in equipment documentation where
appropriate. Make sure these instructions and all other equipment documents are accessible to
persons operating or servicing equipment.
The safety message that follows has a WARNING level hazard.
Failure to comply could result in death or serious injury.
WARNING
ELECTRIC SHOCK
Risk of electric shock. Disconnect power before removing covers and / or disconnect, lock out, and
tag switches before servicing electrical equipment. If you receive even a slight electrical shock, shut
down all equipment immediately. Do not restart the equipment until the problem has been identified
and corrected.
MAXIMUM AIR PRESSURE
Unless otherwise noted in the product manual, the maximum air input pressure is 7.0 bar (100
psi). Excessive air input pressure may damage the equipment. Air input pressure is intended to be
applied through an external air pressure regulator rated for 0 to 7.0 bar (0 to 100 psi).
RELEASE PRESSURE
Release hydraulic and pneumatic pressure before opening, adjusting, or servicing pressurized
systems or components.
BURNS
Hot surfaces! Avoid contact with the hot metal surfaces of heated components. If contact can not be
avoided, wear heat-protective gloves and clothing when working around heated equipment. Failure
to avoid contact with hot metal surfaces can result in personal injury.

GV Series Automated Dispensing Systems
8 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Nordson EFD Product Safety Statement (continued)
Halogenated Hydrocarbon Solvent Hazards
Do not use halogenated hydrocarbon solvents in a pressurized system that contains aluminum components.
Under pressure, these solvents can react with aluminum and explode, causing injury, death, or property damage.
Halogenated hydrocarbon solvents contain one or more of the following elements.
Element Symbol Prefix
Fluorine F “Fluoro-”
Chlorine Cl “Chloro-”
Bromine Br “Bromo-”
Iodine I “Iodo-”
Check the Safety Data Sheet (SDS) or contact your material supplier for more information. If you must use
halogenated hydrocarbon solvents, contact your EFD representative for compatible EFD components.
High Pressure Fluids
High pressure fluids, unless they are safely contained, are extremely hazardous. Always release fluid pressure before
adjusting or servicing high pressure equipment. A jet of high pressure fluid can cut like a knife and cause serious
bodily injury, amputation, or death. Fluids penetrating the skin can also cause toxic poisoning.
WARNING
Any injury caused by high pressure liquid can be serious. If you are injured or even suspect an injury:
• Go to an emergency room immediately.
• Tell the doctor that you suspect an injection injury.
• Show the doctor the following note.
• Tell the doctor what kind of material you were dispensing.
Medical Alert — Airless Spray Wounds: Note to Physician
Injection in the skin is a serious traumatic injury. It is important to treat the injury surgically as soon as possible. Do
not delay treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the
bloodstream.
Qualified Personnel
Equipment owners are responsible for making sure that EFD equipment is installed, operated, and serviced by
qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform
their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of
performing their assigned tasks.