GV Series Automated Dispensing Systems
47www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Setting Password Protection
Use the Password portion of the System Setup screen to set or reset a password. The purpose of a password is to
protect the system settings from unauthorized editing.
NOTES:
• The default is no password protection.
• If the password is forgotten, contact your Nordson EFD representative for assistance.
• A password is limited to 16 numbers or characters.
#
Click Step
1
>
• Click SYSTEM SETUP > OPEN.
2
>
• Under Password, enter a password or make the field blank to
remove a password, then click CHANGE PASSWORD.
The system confirms and immediately implements the
password change:
- If a password was entered, the system will prompt for the
password before opening the System Setup screen.
- If the Password field was blank, no password will be required
to open the System Setup screen.
Item Screen Capture Description
Model drop-
down menu
Sets the dispensing software configuration; this setting must match the
system configuration (model). Any change takes effect upon software
restart.
Expert
For advanced users only.
Light (if
present)
• Default: Allows you to control the light intensity if an external switch is
used to control the light.
• Offset: When the system is in the CCD Mode, automatically changes
the light intensity based on the value entered.
NOTE: The Light settings are present only if an optional light accessory
is installed.
Setting System Parameters (continued)
System Setup Screen Fields (continued)

GV Series Automated Dispensing Systems
48 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Setting Up and Calibrating the System (Required)
Before creating any programs or using the automatic offset update capabilities of the system, you must properly set
up and calibrate the system. Correct system setup and calibration is critical for proper system operation.
The Robot Initial Setup wizard guides you through the complete setup and calibration process. This process must
be performed at initial startup and also after any change to the system.
Examples of system changes include the following:
• Any time a component installed on the Zaxis (such as the syringe barrel or camera) is moved.
• Any time a dispensing tip or nozzle is changed.
Setup and calibration includes the following tasks:
• Verifying the robot model and tip detector selection
• Opening the robot initial setup wizard and focusing the camera
• (Only GV systems with a tip detector) setting up the tip detector*
• Setting the camera-to-tip offset
• Setting a mark
• Setting the camera scale*
• Setting the tip-to-workpiece offset*
• (Only GV systems with a tip detector) testing the system setup and calibration
• (Only GV systems without a tip detector) testing the system setup and calibration
*All required setup and calibration tasks are guided by the Robot Initial Setup wizard. However, the tasks shown above with
an asterisk (*) can be performed individually as needed. Refer to “AppendixB, Non-Wizard Setup Procedures” on page124
for the procedures.
NOTE: Refer to “About Offsets” on page27 for an explanation of offsets.
Verifying the Robot Model and Tip Detector Selection
#
Click Step Reference Image
1
>
• Click SYSTEM SETUP > OPEN.
2
• Under Other, verify the following:
- If your system includes a tip detector, Tip
Detect Device is checked.
- The correct robot model is shown. If
the robot model is not correct, go to
“Changing the Robot Model Selection”
on page57 to select the correct model.
Return here to continue.
• If you made changes, close and reopen the
DispenseMotion software for the changes to
take effect.
3
• Continue to “Setting Up the System
Using the Robot Initial Setup Wizard” on
page49.

GV Series Automated Dispensing Systems
49www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Setting Up the System Using the Robot Initial Setup Wizard
The Robot Initial Setup wizard guides you through all the steps required to properly set up the system, including the
calibration and setting of offsets.
Robot Initial Setup (Step1 Tab): Opening the Robot Initial Setup Wizard and Focusing the Camera
# Click Step Reference Image
1
> >
• Click SYSTEM SETUP > OPEN > ROBOT
INITIAL SETUP.
The Robot Initial Setup wizard opens.
• Perform the actions on tabs 1–6 one at a
time. The actions are also provided in this
manual, starting with the next step, for your
reference as needed.
2
>
• Click the STEP1 tab.
• Jog the tip over the entire workpiece
to ensure that there is at least 5 mm of
clearance between the bottom of the tip to
the highest part of the workpiece.
• Adjust the camera on its bracket until
the camera’s field of view shows the
correct area of the workpiece for setup or
programming.
• Jog the tip to a good location to deposit a
test dispense dot.
• Bring the image on the screen into a sharp
focus. Refer to “Camera” on page18
as needed for instructions on focusing the
camera.
3
• Continue to “Robot Initial Setup (Step 2
Tab): (Only GV Systems With a Tip Detector)
Setting Up the Tip Detector” on page50.