3OM-1343-008_w.pdf - 第134页

3-49 AKFEDT -ID (D03_04) H The height for each individual patterns (unit PCBs) can be corrected. Note When a parameter is set as "H" data in the last line (last step No.), it becomes invalid because "E&quo…

100%1 / 343
3-48
AKFEDT-ID
(D03_03)
Z=theta [deg]
Set an angle of each pattern.
Keep the angle of the reference pattern as "000.00°".
In the gure below, "Pattern 1" is regarded as a reference one.
N
0
:
The center of
is the placement coordinate reference.
O
01
:
Pattern Origin of Pattern 1
O
02
:
Pattern Origin of Pattern 2
O
03
:
Pattern Origin of Pattern 3
O
04
:
Pattern Origin of Pattern 4
Pattern 1 :
Pattern 2 :
90°
Pattern 3 :
180°
Pattern 4 :
270°
X
O
03
O02
O01
O04
Y
Placement Coordinate
Reference (N
0)
Component
Pattern 4
Pattern 3
Pattern 2
Pattern 1
Fig. 3C35 Example of Repetitive Patterns
Note
A numerical value must be entered in increments of 90°. Otherwise, an error will
occur.
0601-002
1.5 Placement Data
3-49
AKFEDT-ID
(D03_04)
H
The height for each individual patterns (unit PCBs) can be corrected.
Note
When a parameter is set as "H" data in the last line (last step No.), it
becomes invalid because "E" is set in the "C (Control Command)" text
box.
(D03_05)
C
Enter some of the following control commands.
Notice
If a control command other than the following ones is used, the step
becomes invalid.
- (hyphen) :
This command handles the steps as those for component
placement.
S :
This command invalidates the steps speci ed as those for
component placement.
C :
This command invalidates the steps speci ed as those for
component placement.
Note:
As for dispensers, these steps become valid.
D :
This command handles the steps as those for component
placement.
Note:
As for dispensers, these steps become invalid.
E :
When placement data (O) is not created, this shows the
end of the steps in the placement data (P).
Note
Con rm that "0" (zero) is set in the "X [mm]", "Y [mm]", and "Z=theta
[deg]" text boxes of the last line (last step No.) and set "E".
(D03_06)
Comment
Set a comment for each step No.
Alphanumeric characters and symbols can be used.
Up to 32 characters (alphanumerics and marks) can be used.
Note
The automatic operation is not affected by these comments.
0601-002
1.5 Placement Data
3-50
AKFEDT-ID
0601-002
2. Editing of Pattern Program
2. Editing of Pattern Program
2.1 "Pattern Program" Window
When the [EDIT] button on the main menu bar is pressed, the "PP. DATA"
window opens together with a submenu bar.
[1]
[2]
[3]
[4]
[5]
[6]
Fig. 3C36 "PP.DATA" Window
[1] List of Model Names
Listed are the registered model names (pattern program names).
[2] [Edit] Button
When pressed, this button opens an edit window for the selected model
(pattern program).
[3] [Create New] Button
When pressed, this button opens the edit window for a new pattern
program.
[4] [Delete] Button
When pressed, this button deletes the selected model (pattern program).