3OM-1343-008_w.pdf - 第88页
3-3 AKFEDT -ID (A01_03) PCB origin offset X (Horizontal), Y (V ertical) [mm] Set the offset values to correct the dif ference between the placement coordinate reference (N 0 ) and the PCB origin (P 0 ). " Plus "…

3-2
AKFEDT-ID
(A01_02)
PCB size
X (Horizontal), Y (Vertical), and T (thickness) [mm]
Set the dimensions of the PCB to be produced.
T (Thickness)
Y (Vertical)
X (Horizontal)
PCB
PCB Flow Direction
Fig. 3C1
When the PCB has a cutout, the following dimensions must be entered.
T (Thickness)
Y (Vertical)
X (Horizontal)
PCB
PCB Flow Direction
Fig. 3C2
•
Data Input Range
X:
50 to 460
Y:
50 to 460
T:
0.5 to 5.0
Note
(a) Be sure to set a correct parameter in the "X (Horizontal)" text
box because the set parameter is used to automatically correct the
placement position when a parameter is selected in the "PCB locate
method" text box in the "PCB transfer Mode Setup" tab sheet.
(b) The set parameter in the "Y (Horizontal)" text box must be used as a
target width for the conveyor width automatic adjustment operation.
(c) "T (Thickness)" is used as a target value for the backup table
ascending position when a PCB is clamped by the clamp plates and
positioned.
0601-002
1.2 Operation Data

3-3
AKFEDT-ID
(A01_03)
PCB origin offset
X (Horizontal), Y (Vertical) [mm]
Set the offset values to correct the difference between the placement
coordinate reference (N
0
) and the PCB origin (P
0
).
"
Plus
"
or
"
Minus
"
can be set in both X and Y coordinates in the
direction of the correction.
Placement Coordinate Reference Point :
For Front Right
Y
PCB Origin(P0)
PCB
X
Placement Coordinate Reference (N0)
PCB Origin(P0)
Y
X
Placement Coordinate Reference (N0)
X
Y
PCB
PCB Origin(P
0)
Placement Coordinate Reference (N0)
Y
X
PCB
PCB Origin(P
0)
Placement Coordinate Reference (N0)
Placement Coordinate Reference Point :
For Rear Left
Placement Coordinate Reference Point :
For Front Left
Placement Coordinate Reference Point :
For Rear Right
PCB
+
+
+
+
+
+
+
+
Fig. 3C3 Example of
"
+
"
(Plus) Direction for Correction
0601-002
1.2 Operation Data

3-4
AKFEDT-ID
Z (Angle) [deg]
Set the offset value for component placement angle.
The set value is added to the
"
Offset Z (deg)
"
of all components in the
placement data (P data).
To correct the angle of component placement counterclockwise, a
parameter must be entered with a plus (+) sign. A minus (-) sign must
be affi xed for clockwise correction.
+{.{{o
-{.{{o
0o
Fig. 3C4
0601-002
1.2 Operation Data