3OM-1343-008_w.pdf - 第200页

5-15 AKFEDT -ID 2.2 Handling Errors Per Feeder When the "Handling Err . Per Fdr" tab is pressed in the "Management Data" window , the following tab sheet appears inside the window . Fig. 3E8 "Han…

100%1 / 343
5-14
AKFEDT-ID
G: component posture (% of Total handling errors)
Shown are the number of reversed component and polarity judgment
errors detected in the recognition process and the percentage of the
errors per total number of pickup errors.
Total handling errors
Shown is the total number of component handling errors.
Zones 1 through 5
1point errors (% of Total PEC recog. errors)
Shown are the total number of errors detected on the rst ducial
mark and the percentage of the detected errors per total number of
all errors detected by the PEC recognition function.
2point errors (% of Total PEC recog. errors)
Shown are the total number of errors detected on the second ducial
mark and the percentage of the detected errors per total number of
all errors detected by the PEC recognition function.
3point errors (% of Total PEC recog. errors)
Shown are the total number of errors detected on the third ducial
mark and the percentage of the detected errors per total number of
all errors detected by the PEC recognition function.
Local ducial errors (% of Total PEC recog. errors)
Shown are the total number of recognition errors in each individual
components and the percentage of the detected errors per total number
of all errors detected by the PEC recognition function.
Total PEC recognition errors
Shown is the total number of errors detected by the PEC recognition
function.
The number of errors detected by the global PEC recognition function
and the total number of errors detected by the BBR recognition function
are displayed.
0607-003
2.1 Machine Performance Data
5-15
AKFEDT-ID
2.2 Handling Errors Per Feeder
When the "Handling Err. Per Fdr" tab is pressed in the "Management Data"
window, the following tab sheet appears inside the window.
Fig. 3E8 "Handling Err. Per Fdr" Tab Sheet
Fig. 3E8-1 "Management Data (Chart)" Window ("Handling Errors per Feeder" Window)
Note
The displayed tab sheet will look different, depending on which option is
selected.
The "Handling Err. Per Fdr" tab sheet is divided further into several tabs and
each tab sheet shows the handling errors per feeder on each individual feeder
bases.
When each tab is pressed, the corresponding tab sheet appears.
0607-003
2.2 Handling Errors Per Feeder
5-16
AKFEDT-ID
(1) Feeder No.
Shown are the feeder Nos.
(2) Total Components
Each text box shows the total number of picked components (number of
pickup actions) for each individual feeders.
(3) A: comp. Missing
Each text box shows the total number of missing components detected
by the linear measure detection sensor for each individual feeders.
(4) B: comp. Missing
Each text box shows the total number of missing components detected
through recognition operation for each individual feeders.
(5) C: comp. Vertical
Each text box shows the total number of vertical component errors
detected by the linear measure detection sensor for each individual
feeders.
(6) D: comp. Recog.
Each text box shows the total number of errors detected through
recognition operation for each individual feeders.
(7) E: comp. Thick
Each text box shows the total number of errors in component thickness
detected by the linear measure detection sensor for each individual
feeders.
(8) F: pick-up Diff
Each text box shows the total number of pickup difference errors
detected in the recognition process for each individual feeders.
(9) G: comp. Posture
Each text box shows the total number of reversed component and
polarity judgment errors detected in the recognition process for each
individual feeders.
(10) Total Errors
Each text box shows the total number of errors detected in (3) through
(9).
0607-003
2.2 Handling Errors Per Feeder