3OM-1343-008_w.pdf - 第65页
1-8 AKFEDT -ID 2.4 Composition of Placement Feeder Location Data The set parameters are used to determine which feeder slot Nos. (Fdr No.) various types of components should be allocated to. Component IDs (types of compo…

1-7
AKFEDT-ID
2.3 Composition of Placement Head/Nozzle Data
This data is used to allocate the nozzles to the specifi ed positions (Nozzle
Allocation Nos.) on the heads.
Set the IDs of the nozzles to be allocated for each individual heads.
Reference
Refer to "1.3 Placement Head/Nozzle Data" in "Chapter 3" for the details
of each item.
B01 Placement Head/Nozzle Table 3A5
Ref. No. Data Name
B01_01 Head 1, 2, 3, and 4
Nozzle 1 through 12, ID Names
2.3 Composition of Placement Head/Nozzle Data
0601-002

1-8
AKFEDT-ID
2.4 Composition of Placement Feeder Location Data
The set parameters are used to determine which feeder slot Nos. (Fdr No.)
various types of components should be allocated to.
Component IDs (types of components to be allocated) must be specifi ed for
each individual feeder bases.
Reference
Refer to "1.4 Placement Feeder Location Data" in "Chapter 3" for the
details of each item according to the reference Nos. (Ref. Nos.).
C01 Feeder Bases #1, #2, #3, #4, and Work Area Table 3A6
Ref. No. Data Name
C01_01 Fdr No.
C01_02 Component ID
C01_03 C (Control Command)
C01_04 Comment
C01_05 Feeder Fixed
C01_06 Feeder Alternate
C01_07 Fdr No.
C01_08 Component Library Comment
C01_09 Dir [deg], Carrier Data Type, Width [mm]
C01_10 Fd. Pitch [mm]
C01_11 Used Parts
2.4 Composition of Placement Feeder Location Data
0601-002

1-9
AKFEDT-ID
2.5 Composition of Placement Data
The set parameters are used to place the components (IDs in the placement
feeder location data) on the points with the specifi ed coordinates in the
designated direction.
One step is allocated for each component to be placed.
Reference
Refer to "1.5 Placement Data" in "Chapter 3" for the details of each item.
D01 Placement Data Un Table 3A7
Ref. No. Data Name
D01_01 Selection of Placement Data Unit
D02 Placement Data (P-data) Table 3A8
Ref. No. Data Name
D02_01 Unit Control
D02_02 Placement Offset
Offsets X [mm] and Y [mm]
Offset Z [deg]
Offset H [mm]
D02_03 Unit PCB Fiducial
Recog Coord X1 [mm] and Y1 [mm]
Recog Coord X2 [mm] and Y2 [mm]
Fiducial Marks FM1 and FM2
D02_04 P-No.
D02_05 X [mm], Y [mm]
D02_06 Z=theta [deg]
D02_07 H [mm]
D02_08 Fdr No.
D02_09 V
D02_10 C (Control Command)
D02_11 Comment
D02_12 Recog Coord X1 [mm] and Y1 [mm]
D02_13 Recog Coord X2 [mm] and Y2 [mm]
D02_14 Fiducial Marks FM1 and FM2
D03 Placement Data (O-data) Table 3A9
Ref. No. Data Name
D03_01 O-No.
D03_02 X [mm], Y [mm]
D03_03 Z=theta [deg]
D03_04 H
D03_05 C (Control Command)
D03_06 Comment
2.5 Composition of Placement Data
0601-002