3OM-1343-008_w.pdf - 第91页
3-6 AKFEDT -ID (A01_04) PCB height offset [mm] Set an offset value as a nozzle descending distance based on the upper surface of the PCB in the component placement section. This offset value applies to all components in …

3-5
AKFEDT-ID
XY-Angle [deg]
Set the offset value for the angle between the machine coordinates
system and the placement coordinates reference system.
To correct the angle of component placement counterclockwise, a
parameter must be entered with a plus (+) sign. A minus (-) sign must
be affi xed for clockwise correction.
X-Direction and Y-Direction
"
Same
"
or
"
Opposite
"
can be selected as the X and Y directions in the
placement reference coordinate system.
Same :
Select this when the direction of the coordinates is
the same as that of the machine coordinates.
Opposite :
Select this when the direction of the coordinates
is opposite, compared with the direction of the
machine coordinates.
1
2
3
2
2
3
3
Y+
X+
X+
Y+
1 : PCB Origin Offset
2 : Unit PCB Origin
3 : Placement Coordinates
Machine Origin
PCB Origin
Machine Coordinate System
Machine Coordinate System
Placement
Coordinate
Reference
Fig. 3C5
Z Angular Orientation
Select one of the following options to determine the Z angular
orientation of the placement coordinate reference point.
Same :
Select this when the angular orientation is the same
as that of the machine coordinates.
Opposite :
Select this when the angular orientation is opposite,
compared with the direction of the machine
coordinates.
0601-002
1.2 Operation Data

3-6
AKFEDT-ID
(A01_04)
PCB height offset [mm]
Set an offset value as a nozzle descending distance based on the upper
surface of the PCB in the component placement section.
This offset value applies to all components in the pattern program.
Normal Cases
Set
"
+0.000
"
(zero) in the text box.
The fi gure below shows that the upper surface of a PCB is maintained
by the PCB support pins at the PCB upper surface reference.
PCB
PCB Upper Surface
Reference
Chute
Backup Pin
Backup Table
Fig. 3C6
Example of Jig PCB Usage
The fi gure below shows that the upper surface of a PCB is lower than
the PCB upper surface reference.
If
"
+ a
"
is set as an offset value at this time, components can be placed
correctly on the PCB.
a
T (Thickness)
Jig PCB
PCB
PCB Upper Surface
Reference
Chute
Fig. 3C7
0601-002
1.2 Operation Data

3-7
AKFEDT-ID
(A01_05)
Placement Reference
Set the placement coordinate reference in this text box.
The reference must be specifi ed according to the input and output
machines.
Rear Left :
The placement coordinate reference is based on the
rear left side and specifi ed as follows.
Y
X
PCB
Placement Coordinate Reference (N
0)
+
+
Fig. 3C8
Front Left :
The placement coordinate reference is based on the
front left side and specifi ed as follows.
Y +
PCB
Placement Coordinate Reference (N
0)
X
+
Fig. 3C9
0601-002
1.2 Operation Data