3OM-1343-008_w.pdf - 第93页

3-8 AKFEDT -ID Front Right : The placement coordinate reference is based on the front right side and speci fi ed as follows. X + Y + PCB Placement Coordinate Reference (N 0 ) Fig. 3C10 Rear Right : The placement coordinat…

100%1 / 343
3-7
AKFEDT-ID
(A01_05)
Placement Reference
Set the placement coordinate reference in this text box.
The reference must be speci ed according to the input and output
machines.
Rear Left :
The placement coordinate reference is based on the
rear left side and speci ed as follows.
Y
X
PCB
Placement Coordinate Reference (N
0)
+
+
Fig. 3C8
Front Left :
The placement coordinate reference is based on the
front left side and speci ed as follows.
Y +
PCB
Placement Coordinate Reference (N
0)
X
+
Fig. 3C9
0601-002
1.2 Operation Data
3-8
AKFEDT-ID
Front Right :
The placement coordinate reference is based on
the front right side and speci ed as follows.
X +
Y +
PCB
Placement Coordinate
Reference (N
0)
Fig. 3C10
Rear Right :
The placement coordinate reference is based on
the rear right side and speci ed as follows.
X
PCB
Placement Coordinate
Reference (N
0)
Y
+
+
Fig. 3C11
Notice
Be sure to set the same reference as the input and output
machines.
If a reference different from the input and output machines is
speci ed, PCBs cannot be produced correctly.
Note
When a different reference is speci ed in the pattern program and the
program is to be used for this machine, be sure to change the reference of
this machine to the different one.
0601-002
1.2 Operation Data
3-9
AKFEDT-ID
(A01_06)
PCB locate Sequence
Select one of the following options as a PCB positioning sequence.
Standard :
Backup and Z Clamp Activated
Mode #1 :
Z Clamp Activated
(A01_07)
PCB transfer Sequence
Select one of the following options as a PCB transfer sequence.
Synchronous Priority :
PCBs are received and transferred at the same
time.
Output Priority :
Priority is given to the PCB transfer after
component placement.
0601-002