5-35 AKFEDT -ID 4. Bypass & Rate Data The corresponding window enables the operator to check the pickup rate and nozzle bypass condition (managed for each individual feeders or nozzles) based on each pickup rate and …

5-34
AKFEDT-ID
(12) Shrtg. of Comp.
Each text box shows the total number of the detected component
shortage errors for each individual feeders.
(13) Component ID
Each text box shows the component IDs for each individual feeders.
(14) Type
Each text box shows the component type.
(15) Width (mm)
Each text box shows the component width.
Note
When one of the above buttons is pressed, the feeder No. with the biggest
parameter under the selected button is displayed in the fi rst line and feeder
Nos. having the subsequent (second, third, fourth, ...) biggest parameters
follow.
That is, parameters are re-arranged in order of error counts, making it easy
to analyze and improve production rate.
When the [Feeder No.] button is pressed, the feeder Nos. are re-arranged
in their initial order (order of slot Nos.).
0607-003
3.3 Handling Errors Per Feeder

5-35
AKFEDT-ID
4. Bypass & Rate Data
The corresponding window enables the operator to check the pickup rate and
nozzle bypass condition (managed for each individual feeders or nozzles)
based on each pickup rate and nozzle bypassing specifi ed in the auto
operation setup data.
When the [Bypass & Rate Dt] button is pressed in the "Bypass & Rate Dt"
window, the "Bypass & Rate Data - [Bypass]" window appears.
[1] [2][4] [3]
Fig. 3E16 "Bypass & Rate Data - [Bypass]" Window
[1] Toolbar
The following buttons are provided.
[Saved Data] Button
When pressed, this button displays the data saved as bypass & rate data.
[Current Data] Button
When pressed, this button displays the current bypass & rate data.
[2] Recording Date & Time
Displayed are the recording date & time and the machine name related
to the bypass & rate data.
0607-003
4. Bypass & Rate Data

5-36
AKFEDT-ID
[3] Tabs and Tab Sheets
The "Bypass & Rate Data - [Bypass]" window is provided with the
following tabs. When each tab is pressed, the corresponding tab sheet
appears inside the window.
Table 3E5
Tabs Description
Head Nozzle Bypass Data
The corresponding tab sheet enables the operator to check the pickup
rate and nozzle bypass condition (managed for each individual feeders
or nozzles) base on each pickup rate and nozzle bypassing specified in
the auto operation setup data.
Feeder Message Rate
The corresponding tab sheet enables the operator to check the pickup
rate, the feeder message rate, and the component ID classifi
ed by each
warning factor on individual feeder Nos. (actual feeder Nos.).
Nozzle Message Rate
The corresponding tab sheet enables the operator to check the pickup
rate and the nozzle message rate classifi
ed by each warning factor of
the nozzles on the individual heads (Head-Noz.).
[4] [Graph Display] Button
When selected, this button graphically displays the status of each item.
Note
The head nozzle bypass data cannot be displayed graphically.
0611-004