6-57 AKFEDT -ID [6] Recog image save Set parameters in the "Object" and "Select" text boxes to analyze the cause of a recognition error in comparison with the error image on the monitor . When "S…

100%1 / 343
6-56
AKFEDT-ID
Guide method
"Warning", "Stop (Cycle stop), or "Pause" can be selected to determine
in which mode the machine should be set when the number of pickup
errors has reached the speci ed error counts before the number of picks
reaches the speci ed number of picks. When "Warning" is selected, a
warning message is issued as machine information. "Stop (Cycle stop)"
stops the machine after one cycle of operation and "Pause" sets the
machine in the "PAUSE" mode.
Note
When both "Error counts" and "# of picks" are set "0" (zero) or "Error
counts" is set to a number larger than "# of picks", no warning message is
issued.
[4] Nozzle message rate
Error counts and # of picks [times]
Set the parameters to show the nozzle No. whose pickup rate has
deteriorated during automatic operation.
When the number of picks has reached the speci ed value, the
parameter in the "Error counts" text box is cleared.
Note
The number of picks and pick-up errors is managed for each individual
nozzles but the parameters of "Error counts" and "# of picks" is equally
re ected on every nozzle.
Guide method
"Warning", "Stop (Cycle stop), or "Pause" can be selected to determine
in which mode the machine should be set when the number of pickup
errors has reached the speci ed error counts before the number of picks
reaches the speci ed number of picks. When "Warning" is selected, a
warning message is issued as machine information. "Stop (Cycle stop)"
stops the machine after one cycle of operation and "Pause" sets the
machine in the "PAUSE" mode.
Note
When both "Error counts" and "# of picks" are set "0" (zero) or "Error
counts" is set to a number larger than "# of picks", no warning message is
issued.
[5] Finished product interval
Mode and Interval [pcs.]
(Not Available)
This is one of the progress information messages displayed as machine
information. When "Monitor" is set in the "Mode" text box, the number
of processed products can be monitored every time the number of
processed PCB
s reaches the speci ed parameter in the "Interval" text
box.
Note
When "0" (zero) is set in the "Interval" text box, the number of processed
products cannot be monitored.
0604-003
2.2 Auto Operation
6-57
AKFEDT-ID
[6] Recog image save
Set parameters in the "Object" and "Select" text boxes to analyze the
cause of a recognition error in comparison with the error image on the
monitor.
When "Save" is set in the "Mode" text box, the image which matches
the parameters in the "Object" and "Select" text boxes is stored in
memory of the recognition board.
Mode
Select one of the following options to determine whether or not the
recognized image should be saved.
Not Save :
The recognized image is not saved.
Save [Recog NG] :
The recognized image is saved only
when the recognition results in "NG"
(No Good).
Save [Recog OK] :
The recognized image is saved only
when the recognition results in "OK".
Save [Recog NG/OK] :
The recognized image is saved when
the recognition results in "NG" or
"OK"
.
Object
Select one of the following options as a recognized object to be saved.
Cmpnt & PEC Recog :
Both images captured through
component and PEC recognition
operations are regarded as object
images to be saved.
Cmpnt Recog :
Only the image captured through a
component recognition operation is
regarded as an object image to be
saved.
PEC Recog :
Only the image captured through a PEC
recognition operation is regarded as an
object image to be saved.
0601-002
2.2 Auto Operation
6-58
AKFEDT-ID
Select
Cmpnt des
Select one of the following options to determine whether or not a
component should be designated for the recognized image to be saved.
No designate :
No component is designated.
Feeder No. :
A feeder No. can be used to designate a
component.
Component ID :
A component ID can be used to designate a
component.
Feeder No.
When "Feeder No." is selected in the "Cmpnt des" text box, it is
required to enter the feeder No. to be designated.
Component ID
When "Component ID" is selected in the "Cmpnt des" text box, it is
required to enter the component ID to be designated.
Beam des
Select "No designate" or "Designate" to determine whether or not a
beam should be designated for the recognized image to be saved.
Beam
When "Designate" is selected in the "Beam des" text box, it is
required to select one of the following options (beams).
A B C D
Nozzle des
Select "No designate" or "Designate" to determine whether or not a
nozzle should be designated for the recognized image to be saved.
Nozzle
When "Designate" is selected in the "Nozzle des" text box, it is
required to enter the No. of the nozzle to be designated.
Nozzle ID des
Select "No designate" or "Designate" to determine whether or not
a nozzle ID should be designated for the recognized image to be
saved.
Nozzle ID
When "Designate" is selected in the "Nozzle ID des" text box, it
is required to enter the nozzle ID to be designated.
0604-003
2.2 Auto Operation