4 Working with the OSC Features 4.7 Automatic Illumination Optimization (from R18-2) Bedienungsanleitung OSC Package User Guide OSC-Paket 11/2018 91 4.7 Automatic Illumination Optimization (from R18-2) If a component of …

100%1 / 102
4 Working with the OSC Features
4.6 Placement of Components with Centering Pins – PininPaste Height Check (from R18-2)
90 Bedienungsanleitung OSC Package User Guide OSC-Paket 11/2018
Step 5: Station software
If necessary, configure the inspection station
under Machine options – Inspection – If snap-in/
pin-in-paste confirmation is needed
.
(Default: Inspect in output area.
When the board enters the output section, a detailed message is displayed.
The message contains:
The position of the board in the machine.
A list including all placement positions on the board which have to be confirmed.
A graphical board overview in which the selected items in the list are highlighted.
There are two options for each row in the list:
Component was placed correctly (DE: Bauelement wurde korrekt bestückt)
The Z-height will be set as good for the Pin in Paste height check.
Repeat measurement
The measured height will be ignored and the user has to confirm the height whenever the next
component is placed. The board keeps marked for inspection.
After setting the results for all placement positions, the settings have to be confirmed.
Step 6: Station software
Check all placement positions at the inspection
station.
Confirm all placement positions with the All
placement positions confirmed button.
After that, the placement will continue automatically.
4 Working with the OSC Features
4.7 Automatic Illumination Optimization (from R18-2)
Bedienungsanleitung OSC Package User Guide OSC-Paket 11/2018 91
4.7 Automatic Illumination Optimization (from R18-2)
If a component of type Non-standard or Connector cannot be sufficiently recognized during teach-
ing at the
station or Vision Teach Station, the illumination can be adjusted automatically.
Prerequisites
The measurement is performed with a component camera (stationary or head camera).
The relevant features must have been described and the component shape specified in
SIPLACE Pro.
The geometry of the component must be described correctly. If the component has not been
described correctly (e.g. connectors are programmed smaller than they are), the illumination
optimization will try to compensate for that.
The position of the component in the image must be known (as result of the component
measurement or specified manually). If the position of the component in the image was spe-
cified manually, all features of the component shape should at least overlap with the visible
features in the image, otherwise inappropriate illumination settings can be calculated.
Restrictions
The illumination is always optimized for the currently available component and then used for
all components with this component shape. Therefore, if the brightness of the components dif-
fers greatly, the calculated setting may be less robust than the default values for other pack-
aging units or manufacturers.
The illumination optimization cannot recognize if a defective component is being used.
Generally, after performing the illumination optimization, the robustness of the measurement
is increased (= fewer rejections), as it is attempted to achieve maximum contrast between the
connectors and the background. Eventually, fewer defects will then be detected, e.g. if a
connector is dirty.
Since the found position may change slightly after performing the illumination optimization, a
new illumination optimization may provide slightly different settings. I.e., it may happen that
the settings of the illumination optimization do not match even with repeated use. This applies
especially when different illumination planes produce very similar brightness values.
4 Working with the OSC Features
4.7 Automatic Illumination Optimization (from R18-2)
92 Bedienungsanleitung OSC Package User Guide OSC-Paket 11/2018
4.7.1 Application Example
The preceding steps in SIPLACE Pro, station software and SIPLACE Vision are assumed.
Step 1: SIPLACE Vision
Important: If the component position could not
be recognized automatically, you must first
manually adjust the position using the arrow and
rotation buttons on the top right.
Click on the Start optimization button in the Set
component position for optimization dialog.
In the next dialog, click on Next.
In the next dialog, click on Accept to accept the
result.
During the optimization, the different illumination planes are simulated and images are displayed
continuously with the current best setting. At the end of the optimization, the measurement is per-
formed with the best illumination setting.