OM-1271-003_w.pdf - 第27页
24 Tg1097-ID-OP 0708-003 [3] "Of fset" Display The offset value (pulse value (mm)) for the selected nozzle stocker is displayed. Master Offset : It shows the deviation from the nozzle stocker designed position …

23
Tg1097-ID-OP
0708-003
8.3 Nozzle Stocker Offset
8.3 Nozzle Stocker Offset
This procedure teaches the offset to secure the nozzle stocker position
(machine coordinate reference). The inclination in direction X from the
recognition mark for the recognized nozzle stocker section, is calculated
and the values are reflected automatically on the nozzle stocker offset in
directions X and Y.
(1) When the [OTHERS] button is pressed on the "TEACHING"
submenu bar, the menu bar for the other teaching functions pops
up.
(2) Press the [NOZ STK OFFSET] button on the pop-up menu bar.
[5]
[1]
[2]
[3]
[4]
Fig.7-4 "NOZZLE STOCKER OFFSET" Window
[1] Select Head Button
The button images showing the head positions are displayed.
Using these images, the PEC recognition camera to be used in the
teaching, is selected.
[2] Nozzle Stocker Select Button
[NST-1], [NST-2] Button
Pressing the [NST-1] or [NST-2] selects the nozzle stocker for
which the offset is displayed.

24
Tg1097-ID-OP
0708-003
[3] "Offset" Display
The offset value (pulse value (mm)) for the selected nozzle stocker is
displayed.
Master Offset :
It shows the deviation from the nozzle stocker designed position
(machine coordinate reference).
The recognition mark (inside) on the nozzle stocker section
is recognized and the values are reflected automatically in the
values in X and Y.
Stocker (1 to 9) :
This section shows the data for each stocker to correct the
deviation from the nozzle stocker designed position.
The recognition mark on the nozzle stocker section is recognized
and the inclination in direction X is calculated.
Then the results are reflected automatically on the values in X
and Y of the nozzle stocker position.
Cmt
: Offset values before teaching
Adj
: Offset values obtained as the result of teaching
[4] Nozzle Stocker Selection Button
[All Noz Stocker] Button
The teaching results are reflected on all the nozzle stockers.
[Desig Noz Stocker] Button
The teaching results are reflected on the designated nozzle
stocker.
[NST-1], [NST-2] Button
Pressing the [NST-1] or [NST-2] selects the nozzle stocker to be
taught.
8.3 Nozzle Stocker Offset

25
Tg1097-ID-OP
[5] Operation Button
[Teach Start] Button
When this button is pressed, the teaching is performed for the
selected nozzle stocker and the results are displayed in [3] on the
right section of the window.
If any mark recognition error occurs, perform the following
manual alignment.
[Mnl Align Mark 2] Button
When the manual alignment teaching is performed, the "Manual
Alignment Operation Guide" window is displayed to perform the
jig mark (left) recognition on the nozzle stocker jig.
[Mnl Align Mark 1] Button
When the manual alignment teaching is performed, the "Manual
Alignment Operation Guide" window is displayed to perform the
jig mark (right) recognition on the nozzle stocker jig.
8.3 Nozzle Stocker Offset
0708-003