P-TOOL说明书.pdf - 第11页

iv Bef ore using F actor y T ools 3.2 Applicable models The following table shows which models of YAMAMA surface mounters and related machines are compatible or incompatible with Factory Tools. List of machines compatibl…

100%1 / 228
iii
Before using Factory Tools
Recommended network configuration
PC for on-line software
Network hub
Give different
IP addresses to
2 LAN cards.
Commercially available anti-virus software
Microsoft debug patch
Computer Browser Service should be stopped.
LAN
card
LAN
card
In-house network
63100-S0-00
Restrictions on communication function
The number of machines and lines are restricted as shown below for machine remote control (data communication) and
line remote control (line control).
•Upto50linescanberegistered.
With RS-232C
•Uptofourmachinescanbeconnectedtoeachcommunicationextensionboard.
•Upto256machinescanberegistered.
With Ethernet
•Upto10machinescanberegistered.
•Upto50linescanberegistered.
Setup error prevention system (option)
To use the Setup error prevention system (option) on Factory Tools, the following PC is required.
WhenusingBT350orBT500:
PC with a free serial port, running an OS on which Factory Tools runs.
WhenusingwirelessBT900:
LAN port and IP address.
c
CAUTION
Use a wireless LAN that conforms to the IEEE802.1 1b standard.
Use of a wireless LAN can only be verified in Japan.
iv
Before using Factory Tools
3.2 Applicable models
The following table shows which models of YAMAMA surface mounters and related machines are compatible
or incompatible with Factory Tools.
List of machines compatible or incompatible with Factory Tools
n
List of machines compatible or incompatible with P-Tool and M-Tool
Machine model Remarks
YS series
Compatible
YS12, YS100, YS88, YS12F,
YS12P, YS24, YS24X, YSP
Incompatible None
YG series
Compatible
YG100, YG100R, YG12, YG88, YG88R,
YG200, YG200L, YG300, YHP-2, YGD,
YGP, YG12F
Incompatible None
Xg series
Compatible
YV100Xg, YV100XgP, YV100XgC,
YV88Xg, YV100XTg, YV180Xg,
THREEM, THREEM2, HSDXg,
YVP-Xg, YCP, YCP-II
Incompatible None
X series
Compatible
YV100X, YV88X, YV100XT, YV180X,
YV100Xe, HSDX
Incompatible None
I/II series
Compatible
YV100-II, YVL88-II, YV112-III, YV64,
YV64D, HSD, YV100, YVL88, YVL80,
YV100D/86D
• VIOS must be Ver. 1.3 or later.
• Machines prior to VIOS Ver. 1.3 will be
compatible by upgrading to Ver. 1.3.
Incompatible
Machines of VIOS Ver. 1.0, Ver. 1.1 or
Ver. 1.2
YVL80 (VIOS Ver.0.8/0.9)
YV120, YV112-I/II
YM series
Compatible None
Incompatible HYPER, TRAD
Others
Compatible None
Incompatible YVP, YHP-1
n
List of machines compatible or incompatible with S-Tool
Machine mode Remarks
YS series
Compatible
YS12, YS100, YS88, YS12F,
YS12P, YS24, YS24X, YSP
Incompatible None
YG series
Compatible
YG100, YG100R, YG88, YG88R,
YG200, YG200L, YG300, YG12F
Incompatible YHP-2, YGD, YGP
Xg series
Compatible
YV100Xg, YV100XgP, YV100XgC,
YV88Xg, YV100XTg
Incompatible
YV180Xg, THREEM, THREEM2,
HSDXg, YVP-Xg, YCP, YCP-II
Others Incompatible
X series, I/II series, YM series, YVP, YHP-
1 etc.
v
Before using Factory Tools
3.3 Board data format
Factory Tools can handle YGX and Printer text and YGZ format board data, as well as VIOS and VIOS text
formats that have been handled with YGOS V1.xx.
The following tables show data formats that can be handled with Factory Tools, Factory Tools.xx,YGOS V1.xx
and YVOSX, and also show data formats that can be used with each machine model.
n
Data formats handled with software
Data format Factory Tools Factory Tools.xx YGOS V1.xx YVOSX V3.xx YVOSX V2.xx
YGX Yes Yes No No No
YGX (Combined) Yes No No No No
VIOS
*1
Yes Yes Yes Yes Yes
VIOS Text Yes Yes Yes Yes Yes
YGZ
*1
Yes, (NO)
*2
Yes No No No
Printer Text
*1
Yes, (NO)
*2
Yes No No No
*1: Used with YVP-Xg and YGP and YCP.
*2: Unavailable on the S-Tool.
n
Data formats used with each machine model
Machine model
Data type
Remarks
YGX
YGX
(Combineda)
VIOS
VIOS
Text
YGZ
Printer
Text
YS series
Dual Lane
Yes Yes
s s
No No
YS series mounters,
YG series mounters
(except YG200/YG200L)
YHP-2, YGD
Yes No
s s
No No
s
Usable, but part of data
cannot be saved.
YG200/YG200L Yes No Yes Yes No No
YVP-Xg, YCP, YCP-II No No No No No Yes
YGP, YSP No No No No Yes
s
s
Usable, but part of data
cannot be saved.
I/II/X/Xg series No No Yes Yes No No
* For compatibility of each machine model with Factory Tools, see the "List of machines compatible or incompatible with
Factory Tools" in the previous section 3.2, "Applicable models".
Reference
If "SAUTO SETUP" is selected when registering a machine or "Default" is selected when saving board data, the following
data formats are automatically specified.
YVP-Xg, YCP : Printer text
YGP : YGZ
YHP-2, YGD : YGX