4-44 4 F eeder Vie wer 4.2.3 Error Message n Error Message in Optimizer ● Interference with Fixed Feeder and Dump Station When the interference with Dump Station and Fixed Feeders that exist in fixed boards, the followin…

4-43
4
Feeder Viewer
n
Dump Station Specification
Set Width information of each Dump Station as follows.
This is Setting in Y.FacT.
1. Launch “Machine Property”.
2. Select “Setting”- “Specification Information”-“Dump Station Specification”.
Dump Station Specification
64466-S0-00
3. Input width of a right and left occupation of Dump Station (by the unit of Millimeter).
Please set as follows according to the kind of the Dump Station.
Type Left (mm) Right (mm)
Motor drive conveyo 40.00 40.00
Air cylinder drive conveyor 75.00 50.00

4-44
4
Feeder Viewer
4.2.3 Error Message
n
Error Message in Optimizer
●
Interference with Fixed Feeder and Dump Station
When the interference with Dump Station and Fixed Feeders that exist in fixed boards, the following error
message is displayed. In that case, move the Fixed Feeders in fixed boards manually.
Error Message
64467-S0-00
4.2.4 Limitations
n
About Optimizer in Machines
This function doesn’t exist in machines now.
Note that it is possible that Optimizer in Machines arranges feeders to the space where interference with
Feeders and Dump Station occurs.
[Solution]
1.Whenexecutingoptimizeatmachines,makesuretheFeederSetConditionis“AllPartsFixed”.
2.UseOptimizerofY.FacTwhenchangingfeedersetposition.
n
About Limitation for “Auto” setting Dump Station
(Optimizer)
1.DumpStationisnotarrangedwhenpartswhichuseDumpStationexistsonlyonfixedboardorstaticcomponents.
2.Ea2733(referto
●
Interference with Fixed Feeder and Dump Station) occurs when fixed feeder (Parts which setting of
“Use Feeder Optimize” is “No” or Feeder Set Condition is “All Parts Fixed”) and Dump station which state is “Auto”
interfere. The Dump Station is not removed automatically in this case.
(Feeder Viewer)
In Feeder Interfere check, it is judged “interfere” when feeders and Dump station which state
is “Auto” interfere.
n
About setup direction for Dump station
Setup direction is not done to Dump Stations.
Setup Dump Station manually according to the setting of each Dump Station and optimizer result.

4-45
4
Feeder Viewer
4.3 For 0 mount point parts
Themountpointdisplayspartsof0bythefeederviewerbythisfunction.Thelayoutisdisplayeddistinguishing
to judge that the mount point from parts of one or more. The mount point is possible and the movement, Move
parts, and Combine parts etc. of set No. are possible as well as parts of one or more.
4.3.1 Setting
Setting is conducted with the “Feeder viewer setting” dialog box started from the “Feeder viewer setting” in the
“Maintenance” menu of the feeder viewer.
Feeder Viewer Setting dialog
It is effective to put the check.
64468-S0-00
Tickingthe“Showpartwith0mountpoint”enablesthefunctionandshowspartswith0mountpoint.
Untickingthecheckboxdisablesthefunctionandpartswith0mountpointwillnotbeshown.