P-TOOL说明书.pdf - 第220页

4-45 4 F eeder Vie wer 4.3 For 0 mount point par ts Themountpointdisplayspartsof0bythefeederviewerbythisfunc tion.Thelayoutisdisplayeddistinguishing to judge that the mount point from parts of one or m…

100%1 / 228
4-44
4
Feeder Viewer
4.2.3 Error Message
n
Error Message in Optimizer
Interference with Fixed Feeder and Dump Station
When the interference with Dump Station and Fixed Feeders that exist in fixed boards, the following error
message is displayed. In that case, move the Fixed Feeders in fixed boards manually.
Error Message
64467-S0-00
4.2.4 Limitations
n
About Optimizer in Machines
This function doesn’t exist in machines now.
Note that it is possible that Optimizer in Machines arranges feeders to the space where interference with
Feeders and Dump Station occurs.
[Solution]
1.Whenexecutingoptimizeatmachines,makesuretheFeederSetConditionis“AllPartsFixed”.
2.UseOptimizerofY.FacTwhenchangingfeedersetposition.
n
About Limitation for “Auto” setting Dump Station
(Optimizer)
1.DumpStationisnotarrangedwhenpartswhichuseDumpStationexistsonlyonfixedboardorstaticcomponents.
2.Ea2733(referto
Interference with Fixed Feeder and Dump Station) occurs when fixed feeder (Parts which setting of
“Use Feeder Optimize” is “No” or Feeder Set Condition is “All Parts Fixed”) and Dump station which state is “Auto”
interfere. The Dump Station is not removed automatically in this case.
(Feeder Viewer)
In Feeder Interfere check, it is judged “interfere” when feeders and Dump station which state
is “Auto” interfere.
n
About setup direction for Dump station
Setup direction is not done to Dump Stations.
Setup Dump Station manually according to the setting of each Dump Station and optimizer result.
4-45
4
Feeder Viewer
4.3 For 0 mount point parts
Themountpointdisplayspartsof0bythefeederviewerbythisfunction.Thelayoutisdisplayeddistinguishing
to judge that the mount point from parts of one or more. The mount point is possible and the movement, Move
parts, and Combine parts etc. of set No. are possible as well as parts of one or more.
4.3.1 Setting
Setting is conducted with the “Feeder viewer setting” dialog box started from the “Feeder viewer setting” in the
“Maintenance” menu of the feeder viewer.
Feeder Viewer Setting dialog
It is effective to put the check.
64468-S0-00
Tickingthe“Showpartwith0mountpoint”enablesthefunctionandshowspartswith0mountpoint.
Untickingthecheckboxdisablesthefunctionandpartswith0mountpointwillnotbeshown.
4-46
4
Feeder Viewer
4.3.2 Display
n
Feeder layout display
Partsofmountpoint0areregisteredinplaninformation,andplanlayoutcomestobedisplayed.
Plan layout
Display by mount point 0
64469-S0-00
The display changes into the plan layout according to the state as follows.
Plan layout
Effective Invalidity Effective Invalidity
Common
parts
including
mount point 0
(no change)
Board
(no change)
At interference
(no change)
Parts
amount
(no change)
Usually
At the drug
(no change)
At selection
(no change)
At
non-active
when
selecting
63400-S0-00