YS12P_YS12F_YG12F_Mainte_E.pdf - 第82页

3-30 3 Periodic maintenance items 4.3 Cleaning and replacing the blow station filter (1 year) … option Thissectiondescribeshowtocleanandreplacethefilterusedinthemachinesequippedwithablowstation (option…

100%1 / 101
3-29
3
Periodic maintenance items
4.2 Checking the R-axis spline belt (1 year)
TherearetwoR-axissplinebelts.Checktheconditionofeachbelt.
n
R-axis spline belt checkpoints
•Isthebeltbecomingfrayedduetocracksandbeltwear?
•Isthebeltsplittingduetocracksordeterioration?
•Isthebelttensiontooloose?Isthebeltitselfloose?
c


cleaning of the spline belt by the user will void the warranty.
Spline for Head 1
Spline belt
R-axis belt (upper belt)
R-axis belt (lower belt)
Belt tensioner
Belt tensioner
Belt tensioner
Belt tensioner
R-axis motor
53345-L6-00
3-30
3
Periodic maintenance items
4.3 Cleaning and replacing the blow station filter (1 year) … option
Thissectiondescribeshowtocleanandreplacethefilterusedinthemachinesequippedwithablowstation
(option).
c


of the blow station by the user will void the warranty.
1
Turn off the air supply and the
power to the machine.
1. Quit the software and turn off the
machine power switch.
2. Turn the air supply/shutoff valve inside
the machine lower left panel to the right,
to stop the air supply.
53346-L6-00
2
Cut the cable ties on the filter.
Using a wire cutter or similar tool, cut the
cable ties that hold the filter unit inside the
blow station stand.
53347-L6-00
3
Disconnect the air hose from one
end of the filter unit and take out
the filter.
1. Disconnect the air hose from one end of
the in-line filter unit.
2. Remove the filter joint caps on both sides
of the filter by rotating them 90 degrees.
3. Pull the transparent case to remove it
and take out the filter.
53348-L6-00
4
Clean the filter.
Use an air blow gun to blow air through the
filter from the inside and from the outside. If
the filter is excessively dirty and cannot be
cleaned, replace it with a new filter.
• Inlinefilter(unit)
KGR-M9934-01X INLINE FILTER
• Filter
KGR-M9934-FOX FILTER, SPARE
Shutting off the air supply
Step 1
Air supply/shutoff valve
Cutting the cable tie
Step 2
Cable tie
Wire cutter In-line filter unit
Taking out the filter
Step 3
Air hose
Filter
Transparent filter case
In-line filter unit
Filter joint caps
3-31
3
Periodic maintenance items
4.4 Checking the nozzle station sensor condition (1 year) … option
Whenthemachineisequippedwithanozzlestation(option),checkthenozzlestationsensorstoseeifthey
areworkingcorrectly.
c


operation may be interrupted due to a nozzle detection error.
e
1
Press the emergency stop button.
The machine should be in emergency stop
to ensure safety during work.
2
Open the nozzle station shutter.
1. Open the [Unit]-[Head] tab.
2. Press the [Nozzle Stn Shutter] button to
open the nozzle station shutter.
54303-L6-10
3
Check the detection status of the
nozzle station sensors.
Check to see if the nozzle station sensors
detect the presence or absence of nozzles.
1. Open the [Unit]-[I/O] tab.
2. From the "Input" drop-down list, select
"NZL STATION".
3. While extracting a nozzle from the nozzle
station and returning it to the same
position, check whether the
corresponding sensor detects the nozzle
correctly.
The detection status on the screen should
read "1" when the nozzle is extracted
from the nozzle station, and should read
"0" when the nozzle is in the nozzle
station.
54306-L6-10
TIP
The nozzle station position No. where a nozzle was
extracted or inserted is displayed on the lower part of
the "Input" status screen.
4
Close the nozzle station shutter.
On the [Unit]-[Head] tab, press the [Nozzle
Stn Shutter] button to close the nozzle station
shutter.
c

If the detection status of a nozzle station sensor is


cleaning of the nozzle station sensors by the user will
void the warranty.
Opening the shutter
Step 2
Checking the nozzle detection status
Step 3
Select "NZL STATION".
Nozzle station position No. is
displayed here.
Shows the presence or absence
of nozzles detected by sensors.