KY8030 Programmers Manual.pdf - 第54页
52 | KY-8030 Series (KYOS-2007001_rev0) 3D In ‐ line Solder Paste Inspection Systems 14) Option Open the "Option " dialog box to speci fy option setti ngs. The "Option" Dialog Box["…

Programmers Manual
| 51
The "Scan" Dialog Box
Ref
Part reference code.
※ Note: You may not use
the same part reference
number twice.
(Count)
The number of pads found /
The total number of pads
scanned
Add
Assign a part reference
code to a group of selected
pads.
Skip
Move to the next pad group.
Zoom In
Zoom in the screen based
on the current center
position.
Zoom Out
Zoom out the screen based
on the current center
position.
Stop
Stop scanning and close the
dialog box.
13) Unit & Coordinate
Open the "Unit & Coordinate" dialog box to specify a display unit and coordinate
system.
The "Unit & Coordinate" Dialog Box
Unit
Select a unit. (Available
units: mm, inches)
Coordinate
1: Lower Left
2: Lower Right
3: Upper Left
4: Upper Right
Select a coordinate system.
Increase X-values to the
right. / Increase Y-values
upward.
Increase X-values to the left.
/ Increase Y-values upward.
Increase X-values to the
right. / Increase Y-values
downward.
Increase X-values to the left.
/ Increase Y-values
downward.

52 | KY-8030 Series(KYOS-2007001_rev0)
3DIn‐lineSolderPasteInspectionSystems
14) Option
Open the "Option" dialog box to specify option settings.
The "Option" Dialog Box["flashs" in box below should read "flashes"]
Max. Board
The maximum length of a PCB
Min. Board
The minimum length of a PCB.
When loading a Gerber file that contains a board with a
maximum/minimum size, make sure that the Gerber parameters are
valid.
※ Caution: If Gerber parameters are not set correctly, it may lead to
incorrect board size or position data, inhibiting normal PCB operation.
When opening a Gerber file in the RS274D format, make sure that the
Gerber parameters entered match the actual size of the PCB.
Max. Pad
The maximum length of a pad.
When performing "Create All Patterns", patterns are retrieved only
when the size of patterns is equal to or less than the Max Pad value.
Check Point
The size of a check point displayed on the screen
Max. Corner of
Rounded Rect.
The maximum offset value for a rounded rectangle.
This value differentiates rectangles and rounded rectangles from other
pattern shapes.
Offset
Offset

Programmers Manual
| 53
Clearance
The clearance range required for the "Create All Patterns" and "Scan
Reference" tasks.
All positions within the clearance range are recognized as the same
position.
※ Note: If the PCB unit is mm, clearance 1 ==> 0.0001 mm.
If the PCB unit is inches, clearance 1 ==> 0.0001 inch.
Exclude flash
Indicates whether a flash will be excluded during create all pattern
process.
Exclude trace
Indicates whether a trace will be excluded during create all pattern
process.
Exclude multi-
pads pattern
Indicates whether adjacent pads will be differentiated during create all
pattern process.
You can prevent adjacent pads from being automatically registered as
a single pattern while performing "Create All Patterns".
Exclude nonbase
pads
Indicates whether flashes and traces in a layer will be excluded during create all
pattern process.
Remove current
pads
Indicates whether all patterns and pads registered will be removed
during create all pattern process.
Check duplicated
codes
Indicates whether duplication of part reference codes will be checked
and whether a warning message will be displayed.
Default
Initialize all settings back to the default settings set at the time of
shipment.
Ú Caution: If an option setting is changed, "Create All Patterns" may not be performed properly.
Ú Note: You can select from the following options for "Create All Patterns":
y Exclude flash
y Exclude trace
y Exclude multi-pads pattern
y Create All Patterns
y Exclude Nonbase pads
y Remove current pads
Ú Note: You can select the following option for "Scan Reference":
y Check duplicated codes