1-56 AKOEMT -ID 4.5 Checking of Industrial Alcohol Hose and Joints Check for industrial alcohol leakage from the hose (including the joints) running between the solvent tank and the cleaning nozzle. Check the following: …

100%1 / 211
1-55 AKOEMT-ID
Note
If air enters the tube running between the solvent tank and the discharge
nozzle, the cleaning solvent may not be discharged soon.
In this case, discharge a little amount of alcohol to let the air escape, using
the [SOLVENT DISPENSER (ON-OFF)] switch.
[SOLVENT DISPENSER (ON-OFF)] Switch
Fig. 4A80
0704-003
4.4 Replenishment of Industrial Alcohol
1-56 AKOEMT-ID
4.5 Checking of Industrial Alcohol Hose and Joints
Check for industrial alcohol leakage from the hose (including the joints)
running between the solvent tank and the cleaning nozzle.
Check the following:
Industrial Alcohol Leakage
Loosened or Deteriorated Hose Joints and Gaskets
Cracks or Any Other Deterioration in Hose
Be sure to always perform this checking before starting the operation of
the machine and after completing a setup operation.
CAUTION
Industrial alcohol leaks are likely to cause fires.
Whenever an industrial alcohol leakage is found, turn off the power
switch of the machine immediately
.
When it is impossible to determine the cause of a leak or to repair
a leak, contact the marketing department or sales agency of Hitachi
High-Technologies.
It may be difficult to detect a leakage because industrial alcohol is a
volatile liquid.
Be sure to carefully confirm that there are no traces of leaks around
joints, etc.
0704-003
4.5 Checking of Industrial Alcohol Hose and Joints
1-57 AKOEMT-ID
4.6 Cleaning Procedure of Cleaning Unit
CAUTION
Set the [OPERATION/SET UP] switch to the “SET UP” side
before work.
Only the person in charge of maintenance should perform this
work.
When the [MAINT. EXCH.] button on the "AUTO OPN." submenu bar is
pressed, the following window appears.
Fig. 4A81
0704-003
4.6 Cleaning Procedure of Cleaning Unit