2-62 AKOEMT -ID T able 4B53 Error ID Error Name, Description, Cause, and Remedy 1901029 Screen Recog. #1 Image around fiducial mark was unstable. 1901030 Screen Recog. #1 Error of mark figure similitude was extensive. 1901…

2-61 AKOEMT-ID
(19 Screen Recognition) Table 4B52
Error ID Error Name, Description, Cause, and Remedy
1901000 Screen Recog. #1
1901001 Screen Recog. #1
[Camera ID] exceeds the range of setting.
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1901003 Screen Recog. #1
[Camera Gain] exceeds the range of setting.
1901004
Screen Recog. #1
[Camera Level] exceeds the range of setting.
190101
1 Screen Recog. #1
[Mark Size D1] exceeds the range of setting.
1901012
Screen Recog. #1
[Mark Size D2] exceeds the range of setting.
1901014 Screen Recog. #1
[Mark Judge Level] exceeds the range of setting.
(Cause 1)
The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
0609-002
2.2 Troubleshooting after Error Display

2-62 AKOEMT-ID
Table 4B53
Error ID Error Name, Description, Cause, and Remedy
1901029 Screen Recog. #1
Image around fiducial mark was unstable.
1901030 Screen Recog. #1
Error of mark figure similitude was extensive.
1901031
Screen Recog. #1
Error of mark similitude or mark size was extensive.
1901032 Screen Recog. #1
Specified mark was not found in window of recog.monitor
.
(Cause 1) The fiducial marks do not conform to the coordinates X and
Y of the fiducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) When the [RESET] button is pressed, the following window opens.
(2)
When the actual fiducial mark is out of the recognition area, move the
camera such that the mark can enter the recognition area. Select the
[Manual Alignment [STAR
T]] button and press one of the arrow buttons
in the “DIRECTION” and one of the “SPEED” buttons. While the [START]
button is being pressed, the camera keeps on moving.
(3) Select the [Retry Recog. [START]] button and press the [START] button.
When the recognition is completed successfully, this window automatically
closes.
(4) When the recognition still failed after the re-recognition operation, move
the camera such that the actual fiducial mark can stay at the fiducial mark
template (located at the center of the cross hair).
Note
Be sure to adjust the position of the fiducial mark as
accurately as possible because the printing accuracy is
affected by this adjustment.
(5) Select the [Man. Align. finished [START]] button and press the [START]
button. The original window resumes.
Note
If the [STOP] button is pressed while the “Manual
Alignment" window is active, the processing is interrupted
and the original window resumes.
Fig. 4B11
0609-002
2.2 Troubleshooting after Error Display

2-63 AKOEMT-ID
Table 4B54
Error ID Error Name, Description, Cause, and Remedy
1901038 Screen Recog. #1
Unavailable fiducial mark polality was set.
1901040 Screen Recog. #1
Unavailable fiducial mark area was set.
1901043 Screen Recog. #1
Recognition system error.
1901056 Screen Recog. #1
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1902000 Screen Recog. #2
1902001 Screen Recog. #2
[Camera ID] exceeds the range of setting.
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1902003 Screen Recog. #2
[Camera Gain] exceeds the range of setting.
1902004
Screen Recog. #2
[Camera Level] exceeds the range of setting.
190201
1 Screen Recog. #2
[Mark Size D1] exceeds the range of setting.
1902012
Screen Recog. #2
[Mark Size D2] exceeds the range of setting.
1902014 Screen Recog. #2
[Mark Judge Level] exceeds the range of setting.
(Cause 1)
The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
0609-002
2.2 Troubleshooting after Error Display