4OM-1322-006_w.pdf - 第188页
2-51 AKOEMT -ID T able 4B42 Error ID Error Name, Description, Cause, and Remedy 1619000 Node Error T able Z axis motor controller node (17) error 1620000 Node Error T able X axis motor controller node (19) error 1621000 …

2-50 AKOEMT-ID
Table 4B41
Error ID Error Name, Description, Cause, and Remedy
1608000 Node Error
Operation Node (1) Error
1609000 Node Error
Relay Secquence Node (2) Error
1610000 Node Error
Inp.&& Outp.Mac. Interface Node (3) Error
161
1000 Node Error
PCB Transfer Node (4) Error
1612000
Node Error
PCB Chuck Node (5) Error
(Cause 1) Node failed in the communication with the host computer.
(Remedy 1)
Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1613000 Node Error
Squeegee Head Node (6) Error
1614000 Node Error
PEC Recog. Node (7) Error
1615000 Node Error
Cleaning Unit Node (8) Error
1616000 Node Error
Blower Unit Node (9) Error
1617000 Node Error
Printing pressure control output node error
1618000 Node Error
Printing pressure control input node error
(Cause 1)
Node failed in the communication with the host computer.
(Remedy 1)
Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
0609-002
2.2 Troubleshooting after Error Display

2-51 AKOEMT-ID
Table 4B42
Error ID Error Name, Description, Cause, and Remedy
1619000 Node Error
Table Z axis motor controller node (17) error
1620000 Node Error
Table X axis motor controller node (19) error
1621000 Node Error
Table Theta axis motor controller node (21) error
1622000
Node Error
PCB Backup axis motor controller node (23) error
1623000 Node Error
T
able Chute Width axis motor controller node (25) error
1624000 Node Error
Squeegee Driving axis motor controller node (27) error
1625000
Node Error
Screen
Y axis motor controller node (29) error
1626000
Node Error
Screen Recog. X axis motor controller node (31) error
1627000 Node Error
PEC Recog.
Y axis motor controller node (33) error
1628000
Node Error
PEC Recog. X axis motor controller node (35) error
1629000 Node Error
L
Conveyor Width axis motor controller node (37) error
1630000 Node Error
R Conveyor Width axis motor controller node (39) error
(Cause 1) The motor controller node failed in the communication with the host computer.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1631000
Pattern Program Data Error
Illegal pattern program.
(Cause 1)
An illegal value is set in the pattern program data.
(Remedy 1) Press the [PRGM. CHECK] button in the “ERROR” window and check the
contents.
After that, set the correct value.
0609-002
2.2 Troubleshooting after Error Display

2-52 AKOEMT-ID
(17 Material Shortage) Table 4B43
Error ID Error Name, Description, Cause, and Remedy
1701000 Squeegee Life Limit
Front squeegee exceeded life limit.
(Cause 1) The frequency of the front squeegee use has exceeded the limitation.
(Remedy 1) Change the front squeegee and select the “Use Count” data fi
eld of the
replaced squeegee in the “Auto Stop Info” tab sheet. After that, press the
[Counter Clear] button.
1702000 Squeegee Life Limit
Rear squeegee exceeded life limit.
(Cause 1)
The frequency of the rear squeegee use has exceeded the limitation.
(Remedy 1) Change the rear squeegee and select the “Use Count” data fi
eld of the
replaced squeegee in the “Auto Stop Info” tab sheet. After that, press the
[Counter Clear] button.
0609-002
2.2 Troubleshooting after Error Display