4OM-1322-006_w.pdf - 第189页

2-52 AKOEMT -ID (17 Material Shortage) T able 4B43 Error ID Error Name, Description, Cause, and Remedy 1701000 Squeegee Life Limit Front squeegee exceeded life limit. (Cause 1) The frequency of the front squeegee use has…

100%1 / 211
2-51 AKOEMT-ID
Table 4B42
Error ID Error Name, Description, Cause, and Remedy
1619000 Node Error
Table Z axis motor controller node (17) error
1620000 Node Error
Table X axis motor controller node (19) error
1621000 Node Error
Table Theta axis motor controller node (21) error
1622000
Node Error
PCB Backup axis motor controller node (23) error
1623000 Node Error
T
able Chute Width axis motor controller node (25) error
1624000 Node Error
Squeegee Driving axis motor controller node (27) error
1625000
Node Error
Screen
Y axis motor controller node (29) error
1626000
Node Error
Screen Recog. X axis motor controller node (31) error
1627000 Node Error
PEC Recog.
Y axis motor controller node (33) error
1628000
Node Error
PEC Recog. X axis motor controller node (35) error
1629000 Node Error
L
Conveyor Width axis motor controller node (37) error
1630000 Node Error
R Conveyor Width axis motor controller node (39) error
(Cause 1) The motor controller node failed in the communication with the host computer.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1631000
Pattern Program Data Error
Illegal pattern program.
(Cause 1)
An illegal value is set in the pattern program data.
(Remedy 1) Press the [PRGM. CHECK] button in the “ERROR” window and check the
contents.
After that, set the correct value.
0609-002
2.2 Troubleshooting after Error Display
2-52 AKOEMT-ID
(17 Material Shortage) Table 4B43
Error ID Error Name, Description, Cause, and Remedy
1701000 Squeegee Life Limit
Front squeegee exceeded life limit.
(Cause 1) The frequency of the front squeegee use has exceeded the limitation.
(Remedy 1) Change the front squeegee and select the “Use Count” data fi
eld of the
replaced squeegee in the “Auto Stop Info” tab sheet. After that, press the
[Counter Clear] button.
1702000 Squeegee Life Limit
Rear squeegee exceeded life limit.
(Cause 1)
The frequency of the rear squeegee use has exceeded the limitation.
(Remedy 1) Change the rear squeegee and select the “Use Count” data fi
eld of the
replaced squeegee in the “Auto Stop Info” tab sheet. After that, press the
[Counter Clear] button.
0609-002
2.2 Troubleshooting after Error Display
2-53 AKOEMT-ID
(18 PEC Recognition) Table 4B44
Error ID Error Name, Description, Cause, and Remedy
1801000 PEC Recog. #1
1801001 PEC Recog. #1
[Camera ID] exceeds the range of setting.
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1801003 PEC Recog. #1
[Camera Gain] exceeds the range of setting.
1801004
PEC Recog. #1
[Camera Level] exceeds the range of setting.
180101
1 PEC Recog. #1
[Mark Size D1] exceeds the range of setting.
1801012
PEC Recog. #1
[Mark Size D2] exceeds the range of setting.
1801014 PEC Recog. #1
[Mark Judge Level] exceeds the range of setting.
(Cause 1)
The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
0609-002
2.2 Troubleshooting after Error Display