4OM-1322-006_w.pdf - 第87页

1-28 AKOEMT -ID Backup Table Z-Axis Guide Bushing Every 6 Months Lubrication (1) Move up the backup table Z axis. (2) Apply grease with a brush or a spatula. Backup Table Z-Axis Ball Screw Every 6 Months Lubrication (1) …

100%1 / 211
1-27 AKOEMT-ID
3.3.6 PCB Chuck Section
Upper Surface of PCB Transfer
Belt
Every Day Cleaning
Remove solder paste and dust
with a vacuum cleaner.
PCB Positioning Side and
Upper Surface
Every Day Cleaning
Remove solder paste and dust with
a vacuum cleaner.
Upper Surface and Pin Hole
Section of Backup Table
Every Week Cleaning
Remove solder paste and dust
with a vacuum cleaner
.
Fig. 4A21
Note
Backup Table Z-Axis Guide
Bushing
Every Month Cleaning
Clean the stopper with an oiled
rag.
Do not leave any waste
threads after cleaning.
Fig. 4A22
0609-002
3.3 Inspection, Cleaning, and Lubrication Spots
1-28 AKOEMT-ID
Backup Table Z-Axis Guide
Bushing
Every 6 Months Lubrication
(1) Move up the backup table
Z axis.
(2) Apply grease with a brush
or a spatula.
Backup Table Z-Axis Ball Screw
Every 6 Months Lubrication
(1) Move up the backup table
Z axis.
(2) Apply grease with a brush
or a spatula.
Fig. 4A23
Torapezoid Screw for Chute Width
Change
(Left Side), (Right Side)
Every 6 Months Lubrication
(1) Move up the backup table
Z axis.
(2) Apply grease with a brush
or a spatula.
Fig. 4A24
0609-002
3.3 Inspection, Cleaning, and Lubrication Spots
1-29 AKOEMT-ID
Linear Guide for PCB Clamping
Every Month Cleaning
Detach the cover and clean the
stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Note
Linear Guide for PCB Clamping
Every 6 Months Lubrication
Detach the cover and apply grease
with a brush or a spatula.
Fig. 4A25
Linear Guide for Chute Width
Adjustment (Left Side)
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Note
Linear Guide for Chute Width
Adjustment (Left Side)
Every 6 Months Lubrication
(1)
Move up the backup table
Z axis.
(2) Apply grease with a brush
or a spatula.
Linear Guide for Chute Width
Adjustment (Right Side)
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Note
Linear Guide for Chute Width
Adjustment (Right Side)
Every 6 Months Lubrication
(1) Move up the backup table
Z axis.
(2) Apply grease with a brush
or a spatula.
Fig. 4A26
0609-002
3.3 Inspection, Cleaning, and Lubrication Spots