4OM-1322-006_w.pdf - 第127页

1-60-5 AKOEMT -ID 1004-001 4.7 Cooling Fan Filter Cleaning Procedure (4) Remove dust on the fan filter using a vacuum cleaner and brush. Note (a) In the case that dust cannot be removed using a vacuum cleaner , dip the fil…

100%1 / 211
1-60-4
AKOEMT-ID
1004-001
4.7 Cooling Fan Filter Cleaning Procedure
4.7.2 Cleaning Procedure for the Fan Filter in the Main Machine
(1) Turn OFF the power to the machine. (Turn OFF the main breaker).
(2) Remove the machine right side cover and front cover.
Front Cover
Right Side Cover
Fig. 4A86-6
(3) Remove the four screws for the fan motor from the fan motor mounting
plate and remove the finger guard and fan filter from the fan motor.
Fan Motor
Fig. 4A86-7
1-60-5
AKOEMT-ID
1004-001
4.7 Cooling Fan Filter Cleaning Procedure
(4) Remove dust on the fan filter using a vacuum cleaner and brush.
Note
(a) In the case that dust cannot be removed using a vacuum cleaner,
dip the filter in water and rub the surface gently using a brush to
remove the dust.
(b) After washing the filter in water without using soap, dry it
completely.
Finger Guard
Fan Filter
Fig. 4A86-8
(5) Attach the fan motor referring to the following figure so that the finger
guard and fan filter attachment operation is performed in the correct
attachment order.
Fan Filter
Fan Motor
Finger Guard
Fan Motor Mounting Plate
Fig. 4A86-9
1-60-6
AKOEMT-ID
1004-001
4.7 Cooling Fan Filter Cleaning Procedure
Note
When the filter is to be attached, attach it with the filter waver pattern
direction set to vertical.
Filter Waver Pattern
Direction set to Vertical