4OM-1322-006_w.pdf - 第209页

2-72 AKOEMT -ID (22 Others) T able 4B63 Error ID Error Name, Description, Cause, and Remedy 2201000 V acuum Pump V acuum sw was not ON, within specifi ed time. (Cause 1) The vacuum plate is not used. (Cause 2) V acuum Lea…

100%1 / 211
2-71 AKOEMT-ID
Table 4B62
Error ID Error Name, Description, Cause, and Remedy
2121000 Illegal Operation
Not printed PCB exist on the table.
(Cause 1) An unprinted PCB was discharged during the automatic operation after an error
was canceled.
(Remedy 1) Remove the unprinted PCB on the table and restart the operation. Click the
table section (illustrated) in the “AUT
O OPN.” window to remove the PCB
from the memory of the machine whenever necessary
.
2122000 Illegal Operation
Screen was not found.
(Cause 1) The screen clamping cancel check sensor (B6F) is turned OFF.
(Remedy 1)
Install the screen and restart the operation. When an error occurs even
though the screen is installed, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
2123000 Illegal Operation
Reference position was not identifi
ed.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Perform the teaching operation again from the beginning.
2124000 Illegal Operation
Screen was on the holder
.
(Cause 1) The screen clamping cancel check sensor (B6F) is turned ON.
(Remedy 1)
Detach the screen and restart the operation. When this error still occurs even
though the screen is detached, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
0609-002
2.2 Troubleshooting after Error Display
2-72 AKOEMT-ID
(22 Others) Table 4B63
Error ID Error Name, Description, Cause, and Remedy
2201000 Vacuum Pump
Vacuum sw was not ON, within specifi
ed time.
(Cause 1) The vacuum plate is not used.
(Cause 2) Vacuum Leakage
(Cause 3) The vacuum switch is defective.
(Remedy 1) When the vacuum plate is not used, specify the vacuum plate in the pattern
program.
(Remedy 2) Check for vacuum leakage between the PCB and the vacuum plate.
(Remedy 3) The vacuum switch might be set incorrectly or the main body of the vacuum
switch might be defective. Contact our service personnel for details.
2202000
Vacuum Pump
Cleaning side change timeover
(Cause 1) The suction changeover cylinder might be malfunctioning or the cylinder sensor
might be defective.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
2203000
Vacuum Pump
Vacuum plate side change timeover
.
(Cause 1) The suction changeover cylinder might be malfunctioning or the cylinder sensor
might be defective.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
0609-002
2.2 Troubleshooting after Error Display
2-73 AKOEMT-ID
0609-002