2-20 AKOEMT -ID T able 4B1 1 Error ID Error Name, Description, Cause, and Remedy 0218000 T able-Z Interlock PEC Recog-Y Axis is not at safety area. (Cause 1) The PEC recognition Y -axis interlock sensor (B46) is defectiv…

2-19 AKOEMT-ID
Table 4B10
Error ID Error Name, Description, Cause, and Remedy
0208000 Table-Z Driver
Driver Over-Heat
(Cause 1) The driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, perform the zeroing operation. If this operation does not reset the
machine to its normal condition, the driver may be defective. Contact our
service personnel for details.
0212000
Table-Z Interlock
PEC Recog-X Axis is not at origin.
(Cause 1)
The PEC recognition X-axis origin photosensor (B351) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Remedy 1) Check how the sensors are working in “Device Check” window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
0214000 Table-Z Interlock
Table-X
Axis approached interlock area.
(Cause 1) The table X-axis interlock sensors (B4E and B4F) are defective.
(Cause 2) The operation timing is shifted from the normal one.
(Remedy 1) Check how the sensors are working in “DEVICE CHECK” window (submenu).
When the sensors are not working, it is required to replace the sensors with
new ones. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
0217000 Table-Z Interlock
(-) Limit error has been detected.
(Cause 1)
The table θ limit (-) photosensor (B213) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) When this error occurs during a manual operation, it is not regarded as a device
error
.
(Remedy 1) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
(Remedy 2) Shut off the power to the machine once and power up the machine. After that,
restart the operation. When the same error still occurs, contact our service
personnel for details.
(Remedy 3) Perform the zeroing operation and restart the operation.
0609-002
2.2 Troubleshooting after Error Display

2-20 AKOEMT-ID
Table 4B11
Error ID Error Name, Description, Cause, and Remedy
0218000 Table-Z Interlock
PEC Recog-Y
Axis is not at safety area.
(Cause 1) The PEC recognition Y-axis interlock sensor (B46) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The table Z axis was activated when the PEC recognition Y axis was not located
at its rear escape position. (during the manual operation)
(Remedy 1) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 3) Perform the zeroing operation and restart the operation.
0219000 Table-Z T
iming
Task has not been completed unable to continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
0220000 Table-Z Data
The data was detected outside of the possible range.
(Cause 1)
The specified data may have exceeded the movable range.
(Remedy 1) Check the parameters in the “Screen Distance [mm]” (“Pattern Program”
window), “Screen Distance” (“OFFSET
DATA” window), and “PCB Transfer
Height” (“OFFSET DATA” window) text boxes.
0221000 T
able-Z Origin
Zeroing Opn. Not Complete.
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
0226000
T
able-Z Overrun
Limit error has been detected.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3)
The driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero
Table Z again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero Table Z. If this operation does not reset the machine to its
normal condition, the driver may be defective. Contact our service personnel
for details..
0609-002
2.2 Troubleshooting after Error Display

2-21 AKOEMT-ID
(03 Table-θ Axis) Table 4B12
Error ID Error Name, Description, Cause, and Remedy
0301000
Table-θ Origin
Zeroing opn. was incompleted, within specifi
ed time.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2)
The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero
Table θ again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero Table θ. If this operation does not reset the machine to its
normal condition, the driver may be defective. Contact our service personnel
for details.
0302000
Table-θ Origin
Detect lost pulse error
.
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1)
Check for any obstacle around the table θ axis and then perform the zeroing
operation. If this operation does not reset the machine to its normal condition,
contact our service personnel for details.
0304000
T
able-θ Overrun
(-) Limit error has been detected.
(Cause 1)
Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3)
The driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero
Table θ again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero Table θ. If this operation does not reset the machine to its
normal condition, the driver may be defective. Contact our service personnel
for details.
0305000
Table-θ Driver
Driver alarm signal was detected.
0308000
Table-θ Driver
Driver Over-Heat
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If this operation does not reset the
machine to its normal condition, contact our service personnel for details.
0609-002
2.2 Troubleshooting after Error Display