4OM-1322-006_w.pdf - 第90页

1-31 AKOEMT -ID T able Z-Axis Guide Bushing Every Month Cleaning Clean the stopper with an oiled rag. Do not leave any waste threads after cleaning. Note T able Z-Axis Guide Bushing Every 6 Months Lubrication (1) Move th…

100%1 / 211
1-30 AKOEMT-ID
3.3.7 Table Section
Tabel X-Axis Linear Guide
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Note
Fig. 4A27
Table X-Axis Ball Screw
Every 6 Months Lubrication
(1) Move the table Z axis up to
the printing position.
(2) Detach the cover located in
front of the table.
(3) Apply grease to the X-axis
ball screw with a brush or a
spatula.
Fig. 4A28
0609-002
3.3 Inspection, Cleaning, and Lubrication Spots
1-31 AKOEMT-ID
Table Z-Axis Guide Bushing
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Note
Table Z-Axis Guide Bushing
Every 6 Months Lubrication
(1) Move the table Z axis up to
the printing position.
(2) Detach the cover located in
front of the table.
(3) Apply grease to the X-axis
ball screw with a brush or a
spatula.
Table Z-Axis Ball Screw
Every 6 Months Lubrication
(1) Move the table Z axis up to
the printing position.
(2) Detach the cover located in
front of the table.
(3) Apply grease to the X-axis
ball screw with a brush or a
spatula.
Fig. 4A29
0609-002
3.3 Inspection, Cleaning, and Lubrication Spots
1-32 AKOEMT-ID
Table -Axis Movable Bearing
Outer Circumference
Every 3 Months after Initial One
Lubrication (NM1)
Apply grease with a brush or a
spatula.
T
abel -Axis Linear Guide
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Note
Tabel -Axis Ball Screw
Every 6 Months Lubrication
Apply grease with a brush or a
spatula.
Fig. 4A30
Tabel -Axis Linear Guide
Every 6 Months Lubrication
Inject new grease from the
grease nipple with a grease gun
from the rear side of the machine.
Use the H-type attachment.
Note
Fig. 4A31
0609-002
3.3 Inspection, Cleaning, and Lubrication Spots