4OM-1322-006_w.pdf - 第182页
2-45 AKOEMT -ID T able 4B36 Error ID Error Name, Description, Cause, and Remedy 1320000 T able Block Stopper PCB stopper error (Cause 1) The position of the upper limit sensor (B70) is shifted from the correct one. (Caus…

2-44 AKOEMT-ID
Table 4B35
Error ID Error Name, Description, Cause, and Remedy
1314000 PCB Transfer Interlock
2 PCB was on table.
(Cause 1)
The overlapped PCB's were transferred.
(Cause 2) Two PCB's were transferred in succession.
(Cause 3) The overlapped PCB detection sensor (B6A) section is not adjusted correctly.
(Remedy 1) Remove the PCB’s and restart the operation.
(Remedy 2) Remove the PCB’s and restart the operation.
(Remedy 3) Contact our service personnel for details.
1315000 T
able Stopper Interlock
PEC Recog-X Axis was running.
1316000
Table Stopper Interlock
PEC Recog-Y
Axis was running.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1317000 T
able Stopper Interlock
PCB was took on table.
(Cause 1) The stopper was moved down when a PCB is still on the table. (during the
manual operation)
(Cause 2) The PCB check sensor (B69) is defective.
(Remedy 1) Remove the PCB and restart the operation.
(Remedy 2)
Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
1318000 Output Cnvr. Stopper Interlock
Output conveyor motor was running.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1319000
Output Cnvr
. Stopper Interlock
PCB was took on output conveyor.
(Cause 1)
A PCB is still on the output conveyor.
(Cause 2) The PCB arrival and passage check sensors (B44 and B45) are defective.
(Remedy 1) Remove the PCB and restart the operation.
(Remedy 2) Check how the sensors are working in “DEVICE CHECK” window (submenu).
When the sensors are not working, it is required to replace the sensors with
new ones. Contact our service personnel for details.
0609-002
2.2 Troubleshooting after Error Display

2-45 AKOEMT-ID
Table 4B36
Error ID Error Name, Description, Cause, and Remedy
1320000 Table Block Stopper
PCB stopper error
(Cause 1) The position of the upper limit sensor (B70) is shifted from the correct one.
(Cause 2) The upper limit sensor is defective.
(Cause 3)
The stopper cylinder is malfunctioning.
(Remedy 1) Readjust the sensor position. (Refer to the separately attached paper.)
(Remedy 2) Check how the sensors are working in “DEVICE CHECK” window (submenu).
When the sensors are not working, it is required to replace the sensors with
new ones. Contact our service personnel for details.
(Remedy 3) Contact our service personnel for details.
1321000 PCB Clamp
PCB chuck missed.
(Cause 1) The PCB had come off when the PCB was clamped.
(Cause 2)
The PCB clamping forward limit sensor (B48) is defective.
(Remedy 1) Adjust the PCB clamping pressure. Set a parameter (deceleration value)
in the “Aft. Clamp Bkup Spd.” text box of “PCB Clamp Offset” in the “PCB
Backup” tab sheet.
(Remedy 2) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
1323000 PCB Clamp
PCB cramp move error.
When the PCB horizontal clamping function was manually activated, the PCB clamping
forward limit sensor (B48) was not turned ON within the specified time. Even if an error
occurs when this manual operation is performed with the PCB set in the table section, it is
not regarded as an error
.
(Cause 1)
The PCB clamping pressure is too low
.
(Cause 2) The PCB clamping forward limit sensor is defective.
(Remedy 1) Adjust the PCB clamping pressure.
(Remedy 2) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
0609-002
2.2 Troubleshooting after Error Display

2-46 AKOEMT-ID
(14 Squeegee Head) Table 4B37
Error ID Error Name, Description, Cause, and Remedy
1401000 Squeegee Up/Down Axis
Table-Z
Axis is not at print pos.
(Cause 1) The table has not moved up yet. (during the manual operation)
(Remedy 1) Move up the table and restart the operation.
1402000 Squeegee Up/Down
Axis
Squeegee Up/Down cylinder moveing error.
(Cause 1)
The position of the upper limit sensors (B60 and B62) is shifted from the correct
one.
(Cause 2) The upper limit sensor is defective.
(Cause 3) The squeegee cylinder is malfunctioning.
(Remedy 1)
Adjust the cylinder sensor position.
(Remedy 2) Check how the sensors are working in “DEVICE CHECK” window (submenu).
When the sensors are not working, it is required to replace the sensors with
new ones. Contact our service personnel for details.
(Remedy 3) Contact our service personnel for details.
1403000 Printing Pressure Assign
Front squeegee printing pressure exceeded upper set range.
1404000 Printing Pressure Assign
Rear squeegee printing pressure exceeded upper set range.
(Cause 1)
The feedback data is corrupted.
(Remedy 1) Press the [FeedBack DataClear] button in the “Printing Pressure” tab sheet.
1405000
Printing Pressure
Assign
Not printing pressure exceeded upper range.
(Cause 1) The output value of the load cell is abnormal.
(Remedy 1) Check for any foreign substances around the squeegee up/down cylinder
and confi
rm that the squeegee is correctly installed. When the same error still
occurs, contact our service personnel for details.
1406000 Printing Pressure
Assign
Printing pressure exceeded upper range.
(Cause 1) The printing pressure got out of the specified one during printing.
(Remedy 1)
Check the parameter set in the “Average” text box of the “Printing Press. Error
Setting” group box in the “OPN. MODE” tab sheet. Increase the value when
the threshold severer than required is specified. (Target V
alue: 50N)
Check if the amount of the supplied solder paste is too much or not.
When the same error still occurs after the above-described checking, contact
our service personnel for details.
0609-002
2.2 Troubleshooting after Error Display