4OM-1322-006_w.pdf - 第166页

2-29 AKOEMT -ID T able 4B20 Error ID Error Name, Description, Cause, and Remedy 0610000 PEC Rcg. Camera X Interlock T able-Z Axis is not at origin. (Cause 1) The table Z axis origin sensor (B171) is defective. (Cause 2) …

100%1 / 211
2-28 AKOEMT-ID
(06 PEC Recognition Camera X Axis) Table 4B19
Error ID Error Name, Description, Cause, and Remedy
0601000 PEC Rcg. Camera X Origin
Zeroing opn. was incompleted, within specified time.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2)
The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe of
f dirt on the sensor and zero the PEC recognition camera X axis again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the PEC recognition camera X axis. If this operation does not
reset the machine to its normal condition, the driver may be defective. Contact
our service personnel for details
0602000 PEC Rcg. Camera X Origin
Detect lost pulse error.
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1)
Check for any obstacle around the PEC recognition X axis and then perform
the zeroing operation. If this operation does not reset the machine to its
normal condition, contact our service personnel for details.
0604000 PEC Rcg. Camera X Overrun
(-) Limit error has been detected.
(Cause 1)
Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3)
The driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe of
f dirt on the sensor and zero the PEC recognition camera X axis again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the PEC recognition camera X axis. If this operation does not
reset the machine to its normal condition, the driver may be defective. Contact
our service personnel for details.
0605000 PEC Rcg. Camera X Driver
Driver alarm signal was detected.
0608000 PEC Rcg. Camera X Driver
Driver Over-Heat
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If this operation does not reset the
machine to its normal condition, contact our service personnel for details.
0609-002
2.2 Troubleshooting after Error Display
2-29 AKOEMT-ID
Table 4B20
Error ID Error Name, Description, Cause, and Remedy
0610000 PEC Rcg. Camera X Interlock
Table-Z Axis is not at origin.
(Cause 1)
The table Z axis origin sensor (B171) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The PEC recognition X axis was activated after the table Z axis had moved up.
(during the manual operation)
(Remedy 1) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 3) Perform the zeroing operation and restart the operation.
0611000
PEC Rcg. Camera X Interlock
PCB stopper was down.
(Cause 1) The PEC recognition X axis was activated after the PCB stopper had moved
down.
(Cause 2) The PCB stopper upper limit (B70) is defective.
(Remedy 1)
Move up the PCB stopper and restart the operation.
(Remedy 2)
Check how the sensor is working in “DEVICE CHECK” window (submenu). If
this operation does not reset the machine to its normal condition, it is required
to replace the sensor with a new one. Contact our service personnel for
details.
0612000 PEC Rcg. Camera X Interlock
PCB warpage protection was down.
(Cause 1) The PEC recognition X axis was activated after the PCB warpage top holder had
moved down.
(Remedy 1) Move up the PCB warpage top holder and restart the operation.
0613000
PEC Rcg. Camera X Interlock
Cleaning nozzle is up.
(Cause 1) The cleaning nozzle lower limit (B81) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3)
The PEC recognition X axis was activated after the cleaning nozzle had moved
up. (during the manual operation)
(Remedy 1) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 3) Perform the zeroing operation and restart the operation.
0609-002
2.2 Troubleshooting after Error Display
2-30 AKOEMT-ID
Table 4B21
Error ID Error Name, Description, Cause, and Remedy
0615000 PEC Rcg. Camera X Timing
T
ask has not been completed unable to continue.
0616000 PEC Rcg. Camera X Data
The data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
0617000 PEC Rcg. Camera X Origin
Zeroing Opn. Not Complete.
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
0609-002
2.2 Troubleshooting after Error Display