4OM-1322-006_w.pdf - 第193页
2-56 AKOEMT -ID T able 4B47 Error ID Error Name, Description, Cause, and Remedy 1802029 PEC Recog. #2 Image around fiducial mark was unstable. 1802030 PEC Recog. #2 Error of mark figure similitude was extensive. 1802031 PE…

2-55 AKOEMT-ID
Table 4B46
Error ID Error Name, Description, Cause, and Remedy
1801038 PEC Recog. #1
Unavailable fiducial mark polality was set.
1801040 PEC Recog. #1
Unavailable fiducial mark area was set.
1801043 PEC Recog. #1
Recognition system error.
1801056 PEC Recog. #1
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1802000 PEC Recog. #2
1802001 PEC Recog. #2
[Camera ID] exceeds the range of setting.
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1802003 PEC Recog. #2
[Camera Gain] exceeds the range of setting.
1802004
PEC Recog. #2
[Camera Level] exceeds the range of setting.
180201
1 PEC Recog. #2
[Mark Size D1] exceeds the range of setting.
1802012
PEC Recog. #2
[Mark Size D2] exceeds the range of setting.
1802014 PEC Recog. #2
[Mark Judge Level] exceeds the range of setting.
(Cause 1)
The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
0609-002
2.2 Troubleshooting after Error Display

2-56 AKOEMT-ID
Table 4B47
Error ID Error Name, Description, Cause, and Remedy
1802029 PEC Recog. #2
Image around fiducial mark was unstable.
1802030 PEC Recog. #2
Error of mark figure similitude was extensive.
1802031
PEC Recog. #2
Error of mark similitude or mark size was extensive.
1802032 PEC Recog. #2
Specified mark was not found in window of recog.monitor
.
(Cause 1) The fiducial marks do not conform to the coordinates X and
Y of the fiducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
“Error ID “1801032”” for details.
1802038 PEC Recog. #2
Unavailable fiducial mark polality was set.
1802040 PEC Recog. #2
Unavailable fiducial mark area was set.
1802043 PEC Recog. #2
Recognition system error.
1802056 PEC Recog. #2
Recog. transaction time over.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1804000 PEC Recog.
Test
1804001
PEC Recog. Test
[Camera ID] exceeds the range of setting.
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
0609-002
2.2 Troubleshooting after Error Display

2-57 AKOEMT-ID
Table 4B48
Error ID Error Name, Description, Cause, and Remedy
1804003 PEC Recog. Test
[Camera Gain] exceeds the range of setting.
1804004
PEC Recog. Test
[Camera Level] exceeds the range of setting.
180401
1 PEC Recog. Test
[Mark Size D1] exceeds the range of setting.
1804012 PEC Recog.
Test
[Mark Size D2] exceeds the range of setting.
1804014
PEC Recog. Test
[Mark Judge Level] exceeds the range of setting.
(Cause 1)
The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1804029 PEC Recog.
Test
Image around fi
ducial mark was unstable.
1804030 PEC Recog. Test
Error of mark figure similitude was extensive.
1804031
PEC Recog. Test
Error of mark similitude or mark size was extensive.
1804032
PEC Recog. Test
Specified mark was not found in window of recog.monitor
.
(Cause 1) The fiducial marks do not conform to the coordinates X and Y of the fiducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Follow the steps below to reset the machine to the normal condition. Refer to
“Error ID “1801032”” for details.
1804038 PEC Recog. Test
Unavailable fi
ducial mark polality was set.
1804040 PEC Recog. Test
Unavailable fi
ducial mark area was set.
1804043 PEC Recog. Test
Recognition system error
.
1804056 PEC Recog. Test
Recog. transaction time over
.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
0609-002
2.2 Troubleshooting after Error Display