00192405-02.pdf - 第17页
User Manual SIPLAC E S-25 HM 1 Introduction, technical data Software Version SR.502.xx 01/2001 US Edition 1.4 Revision index 17 1.4 Revis ion inde x 1 Manual Softw are version Editio n First versi on User Ma nual SR.502.…

1 Introduction, technical data User Manual SIPLACE S-25 HM
1.3 User classification Software Version SR.502.xx 01/2001 US Edition
16
1.3 User classification
The operating software is structured so that certain functions or menus can only by used or called
by appropriately trained personnel. There are three different classes of user: 1
– operators,
– line engineers and
– service engineers.
Access to each class may be password-protected. Chapters containing information for user
classes higher than "operator" contain a reference to the user class concerned in the footer. 1
Operators 1
The operator class consists of any person who has been trained in operation of the machine.
These people are authorized to use any functions associated with operating the machine and may
call up any menus needed to use the machine. 1
Line engineers 1
Line engineers have undergone special training and are authorized to carry out line engineer ac-
tivities, such as creating set-up configurations, determining vision parameters, etc. 1
Service engineers 1
This class is reserved for Siemens engineers, who are trained to carry out servicing work and to
upgrade and retrofit the placement system. 1
WARNING A thorough knowledge of the relevant part of this User Manual is re-
quired before carrying out any work on the machine. All work must be carried out by appropriately
trained and qualified personnel. All warning, caution and danger notes MUST be observed. 1
PLEASE NOTE: The content of this User Manual is not part of or intended to modify a previous or
existing agreement, undertaking or legal relationship. Any undertakings entered into by Siemens
AG result from the purchase contract, which also contains complete and generally applicable
guarantees. Such contractual guarantee provisions are neither extended nor restricted by the in-
formation given in this User Manual. 1

User Manual SIPLACE S-25 HM 1 Introduction, technical data
Software Version SR.502.xx 01/2001 US Edition 1.4 Revision index
17
1.4 Revision index
1
Manual Software version Edition
First version User Manual SR.502.xx 11/2000 US
First edition User Manual SR.502.xx 01/2001 US

1 Introduction, technical data User Manual SIPLACE S-25 HM
1.5 Description of the machine Software Version SR.502.xx 01/2001 US Edition
18
1.5 Description of the machine
1.5.1 Functional description
The automatic placement system is a high-performance placement system with two gantries. A
PCB vision module and a 6 or 12-segment collect&place-head are mounted on each gantry. Col-
lect&place heads equipped with a component vision module pick up the components (CO) from
stationary feeder modules and place them onto the PCB clamped in the PCB conveyor. 1
1
Fig. 1.5 - 1 Overall view of the placement system
(1) 6/12-segment collect&place head with component vision module (gantry 1)
(2) Gantry 1 with PCB vision module
(3) 6/12-segment collect&place head with component vision module (gantry 2)
(4) Gantry 2 with PCB vision module
(5) Stationary component supply (location 1)
(6) Stationary component supply (location 3)
(7) PCB conveyor (dual conveyor option)