5 Station extensions User Manual S IPLACE S-25 H M 5.7 Feeder position recognition Software Version SR.502.xx 01/2001 US Edition 182 5.7 Fe eder po sition rec ognit ion If the feeder modu les are equ ipped w ith posit io…

100%1 / 204
User Manual SIPLACE S-25 HM 5 Station extensions
Software Version SR.502.xx 01/2001 US Edition 5.6 PCB data transfer
181
Å Click on the Machine options button in the basic view.
The Machine options window opens.
Å In the Options box, check the PCB data transfer option for the station concerned.
Å Click on the OK button. The PCB data transfer option is now active.
PLEASE NOTE: The PCB data transfer option can only be used in conjunction with a PCB bar-
code reader. 5
5 Station extensions User Manual SIPLACE S-25 HM
5.7 Feeder position recognition Software Version SR.502.xx 01/2001 US Edition
182
5.7 Feeder position recognition
If the feeder modules are equipped with positioning fiducials, the fiducials can be measured.
If the "Conveyor position detection" function has been selected on the line computer, the function
will also appear in the Machine options. It can then be activated or deactivated at each station.
Fig. 5.7 - 1 Feeder position recognition
PLEASE NOTE 5
The "Feeder position recognition" function is always deactivated when the station is switched on. 5
If a track has been entered in the cluster data, the PCB camera on the feeder module will approach
the position of the centering fiducial. Any centering fiducial offset determined during the measure-
ment will then be assigned to this track and added to the pick-up position during the pick-up op-
eration. 5
User Manual SIPLACE S-25 HM 5 Station extensions
Software Version SR.502.xx 01/2001 US Edition 5.8 Fine calibration
183
5.8 Fine calibration
5.8.1 Overview
Fine calibration involves measuring the machines placement offset and determining the required
correction from this value. The Fine calibration measuring program is integrated into the SITEST
program, and a detailed description of the measuring procedure is given in the Fine calibration
instructions (article no. 00191655-01). 5
CAUTION
The SITEST program is password-protected. It must only be called up and used by Siemens en-
gineers or appropriately trained personnel. 5
5.8.2 System requirements
The following system requirements must be fulfilled in order to use the fine calibration program:5
Machine type S2x, F
4
or later
Station computer software version 406.xx or later
SITEST version 406.xx or later
5.8.3 Measuring equipment and tools
The following are supplied as standard: 5
Mapping plate (glass plate in a metal frame)
Double-sided transparent adhesive film
Lighting unit
Magazine with glass components for the collect&place head and pick&place head with fine-
pitch vision module.
5
The following items must be ordered: 5
Manual tray (waffle tray holder) to hold the magazine for the glass components
(article number 00116430-xx)
5
5