1 Introduction, technical data User Manual SIPLACE S-25 HM
1.7 Connection data for the placement system Software Version SR.502.xx 01/2001 US Edition
22
1.7 Connection data for the placement system
1.7.1 Electrical and pneumatic connection points on the placement system
1
Fig. 1.7 - 1 Electrical and pneumatic connection points on the placement system
(1) Compressed air unit
(2) Connection for compressed air line
(3) Main power filter Z1
(4) Hole for power cable
(5) Service socket
(6) Compressed air supply connection for component changeover table
(7) Power supply connection for component changeover table
(8) Communications connection for component changeover table
(9) LAN connection in the control unit
(10) Main power switch
User Manual SIPLACE S-25 HM 1 Introduction, technical data
Software Version SR.502.xx 01/2001 US Edition 1.7 Connection data for the placement system
23
DANGER
The placement system is supplied with 3 x 400 V or 3 x 208 V (US version) ± 5%, 50/60 Hz main
power voltage. This means that some parts of the system carry potentially lethal voltages - even
when switched off at the main switch. Incorrect handling of the placement system can therefore
result in death or severe injury or considerable damage to equipment. 1
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 1
1 Introduction, technical data User Manual SIPLACE S-25 HM
1.8 Technical data ratings Software Version SR.502.xx 01/2001 US Edition
24
1.8 Technical data ratings
1.8.1 Technical data electrical ratings
1.8.2 Technical data compressed air supply
1.8.3 Technical data compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1) 1
1.8.4 Technical data noise emissions
1.8.5 Technical data permissible ambient factors
Supply voltage 3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 208 VAC ± 5 %; 50/60 Hz (U.S.A.)
Fuses 3 x 16 A (3 x 400 VAC, 3 x 208 VAC)
Total connected load 5 kVA
Total power 2 kW
Power failure up to 20 msec
Compressed air pressure Min. 5.5 bar, max. 8 bar
Compressed air consumption 400 Nl/min.
Operating pressure 5.2 bar (fixed)
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint +3°
Max. noise emission 74dBA
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 to 80%
(but no higher than 45% on average in order to prevent
any possibility of condensation on the machine).