SMW200A_specs_en_3606-8037-22_v2700.pdf - 第15页

Version 27.00, October 2024 Rohde & Schwar z R&S ® SMW200A Vec tor Signal Generator 15 Setting time to < 0.1 dB de viation from final val ue, with GUI upd ate stopped, no r elay switchover , f > 10 MHz, I/Q…

100%1 / 88
Version 27.00, October 2024
14 Rohde & Schwarz R&S
®
SMW200A Vector Signal Generator
Level error
level setting characteristic: auto, temperature range from +18 °C to +33 °C
100 kHz f 3 GHz
< 0.5 dB
3 GHz < f 6 GHz
< 0.7 dB
6 GHz < f 20 GHz
< 0.9 dB
R&S
®
SMW-B1031, R&S
®
SMW-B2031,
R&S
®
SMW-B1040, R&S
®
SMW-B1040N,
20 GHz < f 40 GHz
< 1.1 dB
R&S
®
SMW-B1044,
R&S
®
SMW-B2044,
R&S
®
SMW-B1044N,
R&S
®
SMW-B2044N,
R&S
®
SMW-B1044O,
R&S
®
SMW-B2044O,
20 GHz < f 44 GHz
< 1.2 dB
R&S
®
SMW-B1056,
R&S
®
SMW-B1056N,
R&S
®
SMW-B1056O,
R&S
®
SMW-B1067, R&S
®
SMW-B1067N,
R&S
®
SMW-B1067O,
20 GHz < f 43 GHz
< 1.1 dB
R&S
®
SMW-B1056, R&S
®
SMW-B1056N, R&S
®
SMW-B1056O,
43 GHz < f 56 GHz
level 90 dBm
< 1.2 dB
level < 90 dBm
< 1.5 dB
R&S
®
SMW-B1067, R&S
®
SMW-B1067N, R&S
®
SMW-B1067O,
43 GHz < f 67 GHz
level 90 dBm
< 1.2 dB
level < 90 dBm
< 1.5 dB
Additional level error
I/Q modulation
optimization mode: high quality, fast
< 0.3 dB
pulse modulation
< 0.5 dB
Output impedance, VSWR in 50 Ω system
ALC state: on
R&S
®
SMW-B1003, R&S
®
SMW-B2003, R&S
®
SMW-B1006, R&S
®
SMW-B2006
100 kHz < f ≤ 6 GHz
< 1.9, < 1.5 (typ.)
R&S
®
SMW-B1007, R&S
®
SMW-B2007, R&S
®
SMW-B1012, R&S
®
SMW-B2012,
100 kHz < f ≤ 12.75 GHz
< 2.0, < 1.6 (typ.)
R&S
®
SMW-B1020, R&S
®
SMW-B2020, R&S
®
SMW-B1031, R&S
®
SMW-B2031,
R&S
®
SMW-B1040, R&S
®
SMW-B1040N, R&S
®
SMW-B1044, R&S
®
SMW-B2044,
R&S
®
SMW-B1044N, R&S
®
SMW-B2044N, R&S
®
SMW-B1044O, R&S
®
SMW-B2044O
100 kHz < f ≤ 20 GHz
< 2.1, < 1.7 (typ.)
step attenuator = 0 dB,
20 GHz < f ≤ 38 GHz
< 2.2, < 1.8 (typ.)
step attenuator = 0 dB,
38 GHz < f ≤ 44 GHz
< 2.6, < 2.2 (typ.)
step attenuator ≥ 5 dB,
20 GHz < f ≤ 44 GHz
< 2.1, < 1.7 (typ.)
R&S
®
SMW-B1056, R&S
®
SMW-B1056N, R&S
®
SMW-B1056O,
R&S
®
SMW-B1067, R&S
®
SMW-B1067N, R&S
®
SMW-B1067O
100 kHz < f ≤ 38 GHz
< 2.2, < 1.8 (typ.)
38 GHz < f ≤ 50 GHz
< 2.6, < 2.2 (typ.)
Version 27.00, October 2024
Rohde & Schwarz R&S
®
SMW200A Vector Signal Generator 15
Setting time
to < 0.1 dB deviation from final value, with GUI update stopped, no relay switchover,
f > 10 MHz, I/Q optimization mode: fast, health and utilization monitoring service
(HUMS) off
after IEC/IEEE bus delimiter
3
< 1.2 ms, 1 ms (typ.)
with switching of mechanical step
attenuator, after IEC/IEEE bus delimiter
< 25 ms
R&S
®
SMW-B1044, R&S
®
SMW-B1044N,
R&S
®
SMW-B1044O,
R&S
®
SMW-B2044, R&S
®
SMW-B2044N,
R&S
®
SMW-B2044O,
R&S
®
SMW-B1056, R&S
®
SMW-B1056N,
R&S
®
SMW-B1056O,
R&S
®
SMW-B1067, R&S
®
SMW-B1067N,
R&S
®
SMW-B1067O,
with switching of mechanical step
attenuator,
after IEC/IEEE bus delimiter
< 30 ms
Setting time (list mode)
to < 0.1 dB deviation from final value, with GUI update stopped, no relay switchover,
f > 10 MHz, I/Q optimization mode: fast, health and utilization monitoring service
(HUMS) off
after trigger pulse
3
< 0.8 ms, 0.55 ms (typ.)
with R&S
®
SMW-B711,
R&S
®
SMW-B721, run mode: live
< 1 ms
Interruption-free level setting range
level setting characteristic:
uninterrupted level setting
> 20 dB
Reverse power (from 50 Ω source)
maximum permissible RF power in output frequency range of RF path with
R&S
®
SMW-B1003, R&S
®
SMW-B2003, R&S
®
SMW-B1006, R&S
®
SMW-B2006
frequency options;
Note: The RF path is switched off if the reverse power exceeds a limit
(+27 dBm (meas.), depends on RF frequency).
1 MHz < f 3 GHz
50 W
3 GHz < f 6 GHz
10 W
maximum permissible RF power in output frequency range of RF path with
R&S
®
SMW-B1007, R&S
®
SMW-B2007, R&S
®
SMW-B1012, R&S
®
SMW-B1020,
R&S
®
SMW-B2020, R&S
®
SMW-B1031, R&S
®
SMW-B2031, R&S
®
SMW-B1040,
R&S
®
SMW-B1040N, R&S
®
SMW-B1044, R&S
®
SMW-B2044, R&S
®
SMW-B1044N,
R&S
®
SMW-B2044N, R&S
®
SMW-B1044O, R&S
®
SMW-B2044O, R&S
®
SMW-B1056,
R&S
®
SMW-B1056N, R&S
®
SMW-B1056O, R&S
®
SMW-B1067, R&S
®
SMW-B1067N,
R&S
®
SMW-B1067O frequency options
1 MHz < f 67 GHz
0.5 W
Maximum permissible DC voltage
R&S
®
SMW-B1003, R&S
®
SMW-B2003,
R&S
®
SMW-B1006, R&S
®
SMW-B2006
frequency options
50 V
R&S
®
SMW-B1007, R&S
®
SMW-B2007,
R&S
®
SMW-B1012, R&S
®
SMW-B2012
frequency options
35 V
R&S
®
SMW-B1020, R&S
®
SMW-B2020,
R&S
®
SMW-B1031, R&S
®
SMW-B1040,
R&S
®
SMW-B1040N, R&S
®
SMW-B1044,
R&S
®
SMW-B2044, R&S
®
SMW-B1044N,
R&S
®
SMW-B2044N, R&S
®
SMW-B1044O,
R&S
®
SMW-B2044O, R&S
®
SMW-B1056,
R&S
®
SMW-B1056N, R&S
®
SMW-B1056O,
R&S
®
SMW-B1067, R&S
®
SMW-B1067N,
R&S
®
SMW-B1067O frequency options
0 V
3
R&S
®
SMW-B1007, R&S
®
SMW-B2007, R&S
®
SMW-B1012, R&S
®
SMW-B1020, R&S
®
SMW-B2020, R&S
®
SMW-B1031, R&S
®
SMW-B1040,
R&S
®
SMW-B1040N: temperature > +18 °C.
Version 27.00, October 2024
16 Rohde & Schwarz R&S
®
SMW200A Vector Signal Generator
Measured maximum available output level versus frequency with R&S
®
SMW-B1007, R&S
®
SMW-B2007 frequency options
Measured maximum available output level versus frequency with R&S
®
SMW-B1020, R&S
®
SMW-B2020 frequency options
10
12
14
16
18
20
22
24
26
28
0 2 4 6 8 10 12 14 16 18 20
Level / dBm
Carrier frequency / GHz
10
12
14
16
18
20
22
24
26
28
0 1 2 3 4 5 6 7
Level / dBm