Version 27.00, October 2024 Rohde & Schwar z R&S ® SMW200A Vec tor Signal Generator 35 Pulse width Setting range pulse widths of doub le pulses are independently settable with R&S ® SMW-B13XT option 3.333 ns …

Version 27.00, October 2024
34 Rohde & Schwarz R&S
®
SMW200A Vector Signal Generator
Modulation sources for analog modulation
Internal modulation generator
Shape
sinusoidal
Frequency range
0.1 Hz to 1 MHz
Resolution of setting
0.1 Hz
Frequency uncertainty
< 0.001 Hz + relative deviation of
reference frequency
Multifunction generator (R&S
®
SMW-K24 option)
If two RF paths are installed (signal paths A and B), the multifunction generator can be used either on signal path A or B with one
R&S
®
SMW-K24 option. For the multifunction generator to be used on signal paths A and B simultaneously, two R&S
®
SMW-K24 must
be installed.
The R&S
®
SMW-K24 multifunction generator option consists of three function generators that can be set independently. Two of the
three signal sources can be added with different weighting. The total voltage is limited by the maximum output voltage.
Sources
LF generator 1/2
sine wave, pulse, triangle, trapezoid
noise generator
noise amplitude distribution:
Gaussian, equal
Frequency range
sine wave
0.1 Hz to 10 MHz
pulse, triangle, trapezoid
0.1 Hz to 1 MHz (displayed value)
noise bandwidth
100 kHz to 10 MHz
Resolution of setting
sine wave
0.1 Hz
pulse, triangle, trapezoid
10 ns
noise bandwidth
100 kHz
Frequency uncertainty
< 0.001 Hz + relative deviation of
reference frequency
LF output
Monitoring of resulting modulation signal
for
AM, FM, PM
Source
LF generator 1, LF generator 2, external 1,
external 2, noise generator
Output voltage
V
p
at LF connector, open circuit voltage EMF
Setting range
20 mV to 1 V
Setting resolution
1 mV
Setting accuracy
at 1 kHz
< (1 % of reading + 1 mV)
Output impedance
50 Ω
DC offset
–0.2 V to +2.5 V
Frequency response
sine wave, up to 1 MHz
0.05 dB (meas.)
sine wave, up to 10 MHz
0.1 dB (meas.)
Distortion
f < 100 kHz, at R
L
> 50 Ω, level (V
EMF
) 1 V
< 0.1 %
High-performance pulse generator (R&S
®
SMW-K23 option)
If two RF paths are installed (signal paths A and B), the high-performance pulse generator can be used either on signal path A or B
with one R&S
®
SMW-K23 option. For the high-performance pulse generator to be used on signal paths A and B simultaneously, two
R&S
®
SMW-K23 must be installed.
Pulse modes
single pulse, double pulse
Trigger modes
free run, internally triggered
auto
external trigger
external gate
Active trigger edge
positive or negative
Pulse period
Setting range
20 ns to 100 s
Setting resolution
with R&S
®
SMW-B13XT option
3.333 ns
with R&S
®
SMW-B13, R&S
®
SMW-B13T
options
5 ns

Version 27.00, October 2024
Rohde & Schwarz R&S
®
SMW200A Vector Signal Generator 35
Pulse width
Setting range
pulse widths of double pulses are independently settable
with R&S
®
SMW-B13XT option
3.333 ns to 100 s
with R&S
®
SMW-B13, R&S
®
SMW-B13T
options
5 ns to 100 s
Setting resolution
with R&S
®
SMW-B13XT option
3.333 ns
with R&S
®
SMW-B13, R&S
®
SMW-B13T
options
5 ns
Pulse delay
Setting range
0 ns to 100 s
Setting resolution
with R&S
®
SMW-B13XT option
3.333 ns
with R&S
®
SMW-B13, R&S
®
SMW-B13T
options
5 ns
Double-pulse delay
Setting range
20 ns to 1 s
Setting resolution
with R&S
®
SMW-B13XT option
3.333 ns
with R&S
®
SMW-B13, R&S
®
SMW-B13T
options
5 ns
Uncertainty for pulse timing
pulse timing generated digitally; ensured
by design
relative deviation of reference frequency
External trigger
Delay
trigger to RF output
50 ns (meas.)
Jitter
< 10 ns (meas.)
PULSE/VIDEO/SYNC output
LVTTL signal (R
L
≥ 50 Ω)

Version 27.00, October 2024
36 Rohde & Schwarz R&S
®
SMW200A Vector Signal Generator
I/Q modulation
I/Q modulation performance
Operating modes
external wideband I/Q,
internal baseband I/Q
with R&S
®
SMW-B1044O,
R&S
®
SMW-B2044O, R&S
®
SMW-B1056O,
R&S
®
SMW-B1067O frequency options
internal baseband I/Q
RF modulation bandwidth
RF modulation bandwidth with R&S
®
SMW-B1003, R&S
®
SMW-B2003, R&S
®
SMW-B1006, R&S
®
SMW-B2006, R&S
®
SMW-B1007,
R&S
®
SMW-B2007, R&S
®
SMW-B1012, R&S
®
SMW-B2012, R&S
®
SMW-B1020, R&S
®
SMW-B2020, R&S
®
SMW-B1031,
R&S
®
SMW-B2031, R&S
®
SMW-B1040, R&S
®
SMW-B1044, R&S
®
SMW-B2044, R&S
®
SMW-B1056, R&S
®
SMW-B1067 frequency
options
With internal baseband I/Q, wideband
baseband (R&S
®
SMW-B13XT),
I/Q wideband on
1 MHz ≤ f ≤ 300 MHz
±32 % of carrier frequency
300 MHz < f ≤ 2.5 GHz
±40 % of carrier frequency
f > 2.5 GHz
±1 GHz
With internal baseband I/Q, standard
baseband (R&S
®
SMW-B13 or -B13T),
I/Q wideband on
1 MHz < f ≤ 250 MHz
±32 % of carrier frequency
f > 250 MHz
±80 MHz
With external wideband I/Q inputs,
I/Q wideband on
1 MHz ≤ f ≤ 300 MHz
±32 % of carrier frequency
300 MHz < f ≤ 2.5 GHz
±40 % of carrier frequency
f > 2.5 GHz
±1 GHz
6
RF modulation bandwidth with R&S
®
SMW-B1040N, R&S
®
SMW-B1044N, R&S
®
SMW-B2044N, R&S
®
SMW-B1056N,
R&S
®
SMW-B1067N frequency options
With internal baseband I/Q, wideband
baseband (R&S
®
SMW-B13XT),
I/Q wideband on
1 MHz ≤ f ≤ 300 MHz
±32 % of carrier frequency
300 MHz < f ≤ 2.5 GHz
±40 % of carrier frequency
2.5 GHz < f ≤ 20 GHz
±1 GHz
f > 20 GHz
±275 MHz
With internal baseband I/Q, standard
baseband (R&S
®
SMW-B13 or -B13T),
I/Q wideband on
1 MHz < f ≤ 250 MHz
±32 % of carrier frequency
f > 250 MHz
±80 MHz
With external wideband I/Q inputs,
I/Q wideband on
1 MHz ≤ f ≤ 300 MHz
±32 % of carrier frequency
300 MHz < f ≤ 2.5 GHz
±40 % of carrier frequency
2.5 GHz < f ≤ 20 GHz
±1 GHz
f > 20 GHz
±275 MHz
RF modulation bandwidth with R&S
®
SMW-B1044O, R&S
®
SMW-B2044O, R&S
®
SMW-B1056O, R&S
®
SMW-B1067O frequency
options
7
With internal baseband I/Q, wideband
baseband (R&S
®
SMW-B13XT),
I/Q wideband on
1 MHz ≤ f ≤ 300 MHz
±32 % of carrier frequency
300 MHz < f ≤ 2.5 GHz
±40 % of carrier frequency
2.5 GHz < f ≤ 31.15 GHz
±1 GHz
31.15 GHz < f ≤ 31.75 GHz
±500 MHz
31.75 GHz < f < 37.05 GHz
±225 MHz
37.05 GHz ≤ f < 37.65 GHz
±500 MHz
f ≥ 37.65 GHz
±1 GHz
RF frequency response in specified
RF modulation bandwidth
with external wideband I/Q inputs
I/Q wideband on
f ≤ 44 GHz
< 9 dB, < 6 dB (meas.)
f > 44 GHz
<10 dB
I/Q wideband off
< 5 dB, < 3 dB (meas.)
with internal baseband I/Q, standard
baseband (R&S
®
SMW-B13 or -B13T),
I/Q wideband on, optimization mode:
high quality
< 1.0 dB, < 0.3 dB (meas.)
with internal baseband I/Q, wideband
baseband (R&S
®
SMW-B13XT),
I/Q wideband on, optimization mode:
high quality
< 1.0 dB, < 0.4 dB (meas.)
6
±500 MHz for R&S
®
SMW-B1007, R&S
®
SMW-B2007, R&S
®
SMW-B1012, R&S
®
SMW-B2012.
7
Bandwidth limitation for O options comes with an additional sample rate limitation. Sample rate is limited to 1.2 Gsample in the ranges:
31.15 GHz < f ≤ 31.75 GHz and 37.05 GHz ≤ f < 37.65 GHz. Sample rate is limited to 550 Msample in the range: 31.75 GHz < f < 37.05 GHz.