SMW200A_specs_en_3606-8037-22_v2700.pdf - 第57页
Version 27.00, October 2024 Rohde & Schwar z R&S ® SMW200A Vec tor Signal Generator 57 Wideband baseban d generator (R&S ® SMW-B9 option) – arbitrary waveform mode One or two R&S ® SMW-B9 can be installed…

Version 27.00, October 2024
56 Rohde & Schwarz R&S
®
SMW200A Vector Signal Generator
Interface
Standard
DIG I/Q, in line with
R&S
®
Digital I/Q Interface PAD-R
21
,
I/Q data and control signals, data and
interface clock
Level
LVDS
Connector
26-pin MDR
I/Q sample rate
With source "user-defined", the sample rate must be entered via the parameter
"sample rate". With source "Digital I/Q In", the sample rate will be used based on
information provided by the transmitting device.
Source
user-defined, Digital I/Q In
Sample rate
maximum sample rate depends on
connected receiving device
400 Hz to 250 MHz
Resolution
source: user-defined
0.001 Hz
Frequency uncertainty
source: user-defined
< (1 · 10
−12
+ relative deviation of
reference frequency) · sample rate (nom.)
I/Q data
Resolution
18 bit
Logic format
two’s complement
Bandwidth (RF)
system configuration mode: advanced
0.8 · sample rate
Control signals
markers
3
HS DIQ I/Q interface
Input level
peak level
Setting range
–60 dB to +3 dB, referenced to full scale
Setting resolution
0.01 dB
Crest factor
Setting range
0 dB to +30 dB
Setting resolution
0.01 dB
Adjust level function
automatically determines peak level and
crest factor of input signal
Standard
HS DIG I/Q, in line with
R&S
®
Digital I/Q Interface 40G PAD-R
21
(DIG I/Q 40G), I/Q data and control
signals
Level
LVDS
Connector
QSFP+ / QSFP 28
I/Q sample rate
Source
the sample rate will be used based on
information provided by the transmitting
device
HS digital I/Q In
Sample rate
maximum sample rate depends on connected transmitting device and system
configuration mode
system configuration mode: standard
40G
up to 1.05 GHz
50G
up to 1.25 GHz
system configuration mode: advanced
up to 250 MHz
with R&S
®
SMW-K822 option
up to 500 MHz
with R&S
®
SMW-K823 option
up to 1000 MHz
Resolution
0.001 Hz
Frequency uncertainty
< (1 · 10
−12
+ relative deviation of
reference frequency) · sample rate (nom.)
I/Q data
Resolution
16 bit
Logic format
two’s complement
Bandwidth (RF)
system configuration mode: standard
0.83 · sample rate
Control signals
markers
2
21
R&S
®
Digital I/Q Interface PAD-R is a Rohde & Schwarz internal company guideline for the transmission of digital I/Q data. It is supported by a wide
range of signal generators, signal analyzers and radio communication testers.

Version 27.00, October 2024
Rohde & Schwarz R&S
®
SMW200A Vector Signal Generator 57
Wideband baseband generator (R&S
®
SMW-B9 option) – arbitrary waveform
mode
One or two R&S
®
SMW-B9 can be installed. Their I/Q signals can be assigned a frequency offset.
Prerequisite: R&S
®
SMW-B13XT must be installed.
Waveform length
1 sample to 256 Msample in one-sample
steps
with R&S
®
SMW-K515 option
(memory extension)
1 sample to 2 Gsample in one-sample
steps
Supported file formats
.wv, .mat, .csv, .iq.tar
Nonvolatile memory
hard disk
Sample resolution
equivalent to D/A converter
14 bit
Sample rate
400 Hz to 600 MHz
with R&S
®
SMW-K525 option
400 Hz to 1200 MHz
with R&S
®
SMW-K527 option
400 Hz to 2400 MHz
Sample frequency error
internal clock
< (1 · 10
−12
+ relative deviation of
reference frequency) · sample rate (nom.)
Sample clock source
internal
Bandwidth (RF)
at maximum sample rate,
rolloff to –0.1 dB
500 MHz
at reduced sample rate,
rolloff to –0.1 dB
(The waveform is automatically
interpolated to the internal sample rate of
600 MHz.)
0.833 · sample rate
Bandwidth (RF) with R&S
®
SMW-K525
option
at maximum sample rate,
rolloff to –0.1 dB
1000 MHz
at reduced sample rate,
rolloff to –0.1 dB
(The waveform is automatically
interpolated to the internal sample rate of
1200 MHz.)
0.833 · sample rate
Bandwidth (RF) with R&S
®
SMW-K527
option
at maximum sample rate,
rolloff to –0.1 dB
2000 MHz
at reduced sample rate,
rolloff to –0.1 dB
(The waveform is automatically
interpolated to the internal sample rate of
2400 MHz.)
0.833 · sample rate
Frequency offset
Using the frequency offset, the center frequency of the wanted baseband signal can be
shifted. The restrictions caused by the modulation bandwidth still apply.
Frequency offset setting range
–250 MHz to +250 MHz
with R&S
®
SMW-K525 option
–500 MHz to +500 MHz
with R&S
®
SMW-K527 option
–1000 MHz to +1000 MHz
Frequency offset setting resolution
0.01 Hz
Frequency offset error
< 9 · 10
–6
Hz + relative deviation of
reference frequency · frequency offset
(nom.)
Triggering
A trigger event restarts I/Q generation. The I/Q signal is then synchronous with the
trigger (with a specific timing jitter).
Trigger source
event triggered via GUI or remote
command
internal
event triggered by other baseband
generator
internal (baseband A/B)
event triggered by external trigger signal
external
Trigger modes
The signal is generated continuously.
auto
The signal is generated continuously.
A trigger event causes a restart.
retrig
The signal is started only when a trigger
event occurs. Subsequent trigger events
are ignored.
armed auto
The signal is started only when a trigger
event occurs. Every subsequent trigger
event causes a restart.
armed retrig

Version 27.00, October 2024
58 Rohde & Schwarz R&S
®
SMW200A Vector Signal Generator
The signal is started only when a trigger
event occurs. The signal is generated
once.
single
External trigger input
selectable from USER 1, 2, 3 on front
panel, or USER 4, 5, 6 on rear panel
Connector type
USER 1, 2, 3 on front panel,
USER 4, 5, 6 on rear panel
BNC female
Input level
0 V to 3 V (nom.)
Threshold
USER 1, 2, 3
settable from 0.1 V to 2.0 V
USER 4, 5, 6
settable from 0.1 V to 2.0 V
Input damage voltage
–0.5 V, 3.8 V
Input impedance
selectable
1 kΩ or 50 Ω (nom.)
Trigger jitter
±1.67 ns
External trigger delay
Setting range
0 sample to 2.147 · 10
9
sample
Setting resolution
0.4 ns
External trigger inhibit
Setting range
0 sample to
(21.47 s · sample rate) sample
Setting resolution
1 sample
External trigger pulse width
> 7.5 ns
Marker signals
Number of marker signals
3
Operating modes
unchanged, restart, pulse, pattern, ratio
Marker outputs
selectable from USER 1, 2, 3 on front
panel or USER 4, 5, 6 on rear panel
Connector type
USER 1, 2, 3 on front panel,
USER 4, 5, 6 on rear panel
BNC female
Level
LVTTL
Marker delay
Setting range
0 sample to (waveform length – 1) sample
Setting resolution
1 sample
Marker duration
Minimum value
sample rate ≤ 300 Msample/s
1 sample
300 Msample/s < sample rate ≤
600 Msample/s
2 sample
600 Msample/s < sample rate ≤
1200 Msample/s
4 sample
1200 Msample/s < sample rate ≤
2400 Msample/s
8 sample
Multisegment waveform mode
Number of segments
1 to 1024
Changeover modes
GUI, remote control
Extended trigger modes
same segment, next segment, next
segment seamless, sequencer
Seamless changeover
output up to end of current segment,
followed by changeover to next segment
Sequencer play list length
max. 1024
Sequencer segment repetitions
max. 1 048 575
Multicarrier waveform mode
Number of carriers
max. 512
Total RF bandwidth
max. 500 MHz
with R&S
®
SMW-K525 option
max. 1000 MHz
with R&S
®
SMW-K527 option
max. 2000 MHz
Carrier spacing
Setting range
depends on number of carriers and signal
RF bandwidth
Setting resolution
0.01 Hz
Crest factor modes
maximize, minimize, off
Signal period modes
longest file, shortest file, user (max. 1 s)
Single carrier gain
Setting range
–80 dB to 0 dB
Setting resolution
0.01 dB
Single carrier start phase
Setting range
0° to 360°
Setting resolution
0.01°