00198706-01_AI_Stationaere_Kamera_25_33_GigE_SXV3_DE_EN.pdf - 第69页

3 Installation 3.4 Preparatory work on the cameras Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary Camera Type 25/33 (GigE) 03/2021 69 3.4 Preparatory work on the…

100%1 / 94
3 Installation
3.2 Installation position
68 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary
Camera Type 25/33 (GigE) 03/2021
3.2 Installation position
Fig.8: Installation position of stationary cameras
1 NC / pin magazine Q10 (Smart Pin
Support option)
2 FC camera / 3D coplan module / pin
magazine L10 (Smart Pin Support
option)
Loc 1 Location 1 Loc 2 Location 2
3.3 Preparatory work on the machine
Remove the component trolley/WPC from the camera installation position.
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}55]
Dismantle the waste tape chute.
4.1.1 "Replacing the Waste Tape Chute" [}81]
Dismantle the reject bin holder.
You may have to move out the COTi out a little to improve the accessibility.
4.1.2 "Replacing the SX1/SX2 COT insert assembly" [}82]
3 Installation
3.4 Preparatory work on the cameras
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary
Camera Type 25/33 (GigE) 03/2021
69
3.4 Preparatory work on the cameras
NOTICE
The following tasks are principally the same for both camera types. Any relevant differ-
ences will be mentioned explicitly.
Removing the upper section and cover
Fig.9: Removing the upper section and bottom cover
Pull the top section(1) straight up and off the bottom section.
Press the bottom cover(2) out of the pins on the left and right(3) and swing the cover for-
wards(4)
.
Lift the cover slightly(5) and take off.
Fig.10: Camera lower parts for IC camera (SST33) and FC camera (SST25)
3 Installation
3.4 Preparatory work on the cameras
70 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary
Camera Type 25/33 (GigE) 03/2021
Setting the camera
Set the DIP switch S1 as follows:
DIP switch S1 for SST25 and SST33:
Switch Status Signal name Description
S1.1 OFF VCU_CODE OFF: normal operation
ON: Reset
Location 1 Location 2 Location 3 Location 4
S1.2 ON/OFF *) PORTAL_ID_0 OFF ON OFF ON
S1.3 ON/OFF *) GANTRY_ID_1 OFF OFF ON ON
S1.4 OFF SMD_LED OFF: standard LED
ON: SMD LED
S1.5 OFF CAN_H OFF: with CAN terminator
ON: without CAN terminator
S1.6 ON/OFF CAN_GROUP OFF: FC camera
ON: IC camera
*) Set the location at which the stationary camera is fitted. There are no locations 3 or 4 on the
SIPLACE SX1/SX2.
See also
2 4.2.1 "PCBs Stationary Cameras" [}90]