00198706-01_AI_Stationaere_Kamera_25_33_GigE_SXV3_DE_EN.pdf - 第79页
3 Installation 3.8 Final work Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary Camera Type 25/33 (GigE) 03/2021 79 3.8 Final work ► Hook in the housing for the low…

3 Installation
3.7 Fitting the reject bin (FC camera only)
78 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary
Camera Type 25/33 (GigE) 03/2021
Fitting the sensor
Fig.25: Reject bin sensor
► Fit the holder(1) for the sensor, sup-
plied with the "Verify component reject
bin, SX1/2" [00519848‑xx], and fix with
two screws.
► Fit the sensor. This is located on the
COT insert.
See also the assembly instructions for
the "Verify component reject bin SX1/
SX2, DE+EN" [00196615‑xx]
Fig.26: Reject bin
► Insert the reject bin(1).

3 Installation
3.8 Final work
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary
Camera Type 25/33 (GigE) 03/2021
79
3.8 Final work
► Hook in the housing for the lower section of the camera. This is either screwed or hooked into
place, depending on your camera type.
Fig.27: Review
► Carefully place the camera upper sec-
tion (illumination unit) onto the camera
lower section.
Make sure that the camera upper sec-
tion is pushed in as far as the stop.
CAUTION!
The upper edges of the cameras
must be underneath the conveyor
top edge.
.
► Make sure that the glass surface is clean. Clean the mirror/glass surface with a microfiber
cloth, if necessary.
► If the COT insert has been moved or removed, fit this and the side cover again.
4.1.2 "Replacing the SX1/SX2 COT insert assembly" [}82]
► Hook the waste tape slide back into place.
► Make sure that there are no objects in the travel area of the gantry and remove any which are.
► Start the machine and move the component trolley back into the machine.
Configuration and calibration
Fig.28: Select operator level
► Select the button.
► Select the button.
► Switch over to the operator level Ma-
chine service.
ð The button will be shown.

3 Installation
3.8 Final work
80 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary
Camera Type 25/33 (GigE) 03/2021
Fig.29: Configuration
► Configure the installed camera, at the
relevant location, in the station software
(Machine configuration
menu).
Fig.30: Calibration
► Select --> Automatic Cali-
bration.
► Select Calibration of fiducials, cam-
eras and heads and the relevant
gantry.
► Follow any other instructions on the
screen (e.g. prerequisites).
► Select Start.
ð After calibration, the camera will be
ready for use.
Perform the next steps, if necessary:
► Change the machine configuration for the new camera in SIPLACE Pro.
► Perform placement program optimization for the line.