00198706-01_AI_Stationaere_Kamera_25_33_GigE_SXV3_DE_EN.pdf - 第76页
3 Installation 3.6 Electrical connections 76 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary Camera Type 25/33 (GigE) 03/2021 Fig.21: Cables for IC and FC camera…

3 Installation
3.6 Electrical connections
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary
Camera Type 25/33 (GigE) 03/2021
75
Electrical connections for IC and FC camera
Fig.20: Connecting the IC camera to the FC camera
IC IC camera, type SST33 FC FC camera, type SST25
VBI GigE cable run from the machine (from
the Vision Base Interface)
CAN CAN cable
1 Multiplexer on the FC camera 2 Input on the multiplexer (from BoxPC)
3a Output on multiplexer to FC camera 4a Output on multiplexer to IC camera
3b Input on FC camera 4b Input on IC camera
► Disconnect the GigE cable, leading away from the machine, from the IC camera connec-
tion(4b)
and connect it to the FC camera multiplexer connection(2).
► Check whether the cable "cable: extension camera bus IC/FC camera" [03106367‑xx] is
present between the connections(3a)
und(3b). If not, connect the two connections.
► Use the GigE cable supplied "cable: extension camera bus IC/FC camera" [03106367‑xx] with
the retrofit kit to connect the connections(4a)
and(4b).

3 Installation
3.6 Electrical connections
76 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary
Camera Type 25/33 (GigE) 03/2021
Fig.21: Cables for IC and FC camera
► Connect the CAN cable(1) leading from the machine to the camera CAN connections.
► Connect the power supply cable(2) to the FC camera (X4) and the IC camera (X4 or X5).
Fig.22: Connecting the IC camera
► Connect the camera cable (1), the CAN
bus cable (2)
and the power supply
cable (3)
to the stationary camera, ac-
cording to the respective camera con-
figuration.

3 Installation
3.7 Fitting the reject bin (FC camera only)
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Stationäre Kamera Typ 25/33 (GigE) Stationary
Camera Type 25/33 (GigE) 03/2021
77
3.7 Fitting the reject bin (FC camera only)
When using the "stationary camera for CPP head" option, you need to fit an additional reject bin for
components >36x36mm. This is identical to the Twin reject bin.
This reject bin is included in the delivery packages for the stationary camera and the HRK for
SIPLACE Twin.
Parts
Quantity Designation Item no.
1 Holder for reject bin P001 03063283-xx
2 ISO 4762 - M 6 x 10-A2-70 03042571-xx
1 Reject bin assembly 03072806-xx
You also need the "Verify component reject bin, SX1/2" [00519848‑xx].
Fitting the holder
Fig.23: Reject bin screw points on the support plate assemblies
Fig.24: Holder (example of location 2 shown)
► Use the two fastening screws (1)
(M6x10) to fit the holder to the support
plate assembly.