00193794-11_VD_SSW 505.05_de en.pdf - 第32页

Software Version Description, Station Software 505.05 07/2008 Edition 5.4 New S feeder: Shutterless S feeder 3x8mm SL The station software supports a new S feeder type, called "Shutterless S Feeder, 3x8mm SL" T…

100%1 / 150
Software Version Description, Station Software 505.05 07/2008 Edition
932 -1 -1 0 0 0 0 0 0 4200 3
933 -1 -1 0 0 0 0 0 0 5500 3
934 -1 -1 0 0 0 0 0 0 5000 3
935 -1 -1 0 0 0 0 0 0 6000 3
936 -1 -1 0 0 0 0 0 0 5500 3
PipZSchwellwert: Threshold value as of which the nozzle is detected as missing
(Z_actual – Z_target >= Z_Threshold)
PipCheckMode:
0:off
1: on (warning in case of error)
2: Machine immediately on (FE, fatal error);
3 Machine stops after head cyclus mit FE
4: Fatal error (head reference run)
5.3 Connection of line computers and monitoring of the MaDaMas
data
As of this station software version it is possible to connect line computers as of the line computer
version 503.06 (Item no. 00193520-xx) for the following machines:
- HS-50, HS-60
- S-25, S-27
There, any features of the station software 503 are supported.
Restrictions
The connection of the line computers is not possible for the machines HF and HF3.
31 of 150
Software Version Description, Station Software 505.05 07/2008 Edition
5.4 New S feeder: Shutterless S feeder 3x8mm SL
The station software supports a new S feeder type, called "Shutterless S Feeder, 3x8mm SL"
The feeder has two pickup positions:
- one for components with 0,8mm width
- one for components with > 0,8 mm width
The functionality and properties of the shutterless s feeder is the same as for standard S feeder.
Restrictions
The shutterless S feeder requires SIPLACE Pro 5.0.
5.5 Support of OIS/SIS
Two OIS events were added.
Thus, the station software notifies OIS, whether or not the machine is in stand alone mode.
5.6 Fine calibration enabled
As of this version the fine calibration is unrestricted enabled .
5.7 Synchronization of data provision
Integration of the "Mobilink" patch
In order to avoid data provision problems on a job change, the Setup Center only sends the data to
the station when data preparation has been completed and the new job has been specified by
SIPLACE Pro. The Setup Center and the station are synchronized when a job is specified.
5.8 Revision of the dual conveyor
Up to now, the PCB barcode was restricted to 2 x 12 characters on the synchronous dual conveyor.
This restriction has been lifted. 2 x 40 characters are permitted.
32 of 150
Software Version Description, Station Software 505.05 07/2008 Edition
5.9 External reading of the machine ID
The machine ID can be read by the SIPLACE Pro software as for version 3.0. (station computer
interface). The Machine ID is
prerequisite for the following software:
- Setup Center as for version 2.2
- OIS as for version 4.1
- SIPLACE Explorer as for version 2.1
You are asked for the machine id when installing the station software. For details see the installation
manual (00193796-xx).
5.10 Improved placement quality
Placement quality has been improved in the following respects:
- Minimization of missing components on the board
- Detection of missing components on the board
- Minimization the risk of head crashes
This was achieved by implementing additional functions.
- vacuum check for detecting placement errors
- any monitoring functions:
valve plunger position
lower light barrier
15 VDC power supply
upper light barrier of the DLM head
stepper motor boards (short cut monitoring)
dp switch-in function
Note:
On the GUI, additional error messages could appear during the placement process. Because
of the additional monitoring functions which have been implemented to improve the placement
quality.
Vacuum check
In order to detect missing components and placement errors, an additional vacuum measurement
and the associated evaluation have been implemented.
33 of 150