00193794-11_VD_SSW 505.05_de en.pdf - 第72页
Software Version Description, Station Software 505.05 07/2008 Edition 6 Corrected errors SC software version 505.05 contains all the error corrections of predecessor versions up to SC software version 505.04 SP2. Note: I…

Software Version Description, Station Software 505.05 07/2008 Edition
5.44.3 All the features of a 504 system controller
The following description lists all the features of version 504.xx of the software that are also
contained in version 505.xx.
Note:
For a detailed description, see the 504.01 software version description.
- Head modularity, C&P head 6/12 on Gantry 1
- Twin head on gantry 2
- Twin Head nozzle changer
- Adapted nozzle changer for 6- nozzle and 12-nozzle C&P head
- New reject bin for 6- nozzle and 12-nozzle C&P head
- MTC 2 on locations 2 and 4
- New glass mapping plate for single and dual conveyor systems
- Stationary IC and FC cameras
- New board for multicolor camera
- SIPLACE Mobile Verifier (SMV) component barcode reader
- 2D PCB barcode reader
- GEM 504: Integration of the Twin Head and switch to µm
- Traceability 504: Support for MTC 2
- OIS 2.2: Support for the HF machine type
- Synchronous dual conveyor with PCB barcode operation
- Twin Head fine calibration
- Safe mode "Reduced speed": Slow travel of star and gantry axes with closed cover
- Emergency stop without PCB check in output conveyor
- Emergency operation: Deactivate placement area (no PCB placement, just transportation
through the machine)
71 of 150

Software Version Description, Station Software 505.05 07/2008 Edition
6 Corrected errors
SC software version 505.05 contains all the error corrections of predecessor versions up to SC
software version 505.04 SP2.
Note:
Information can be found in the "Errors that have been eliminated" chapters of the following
version descriptions:
Version description 502.01 SP 5 (Item number: 00193160-05)
Version description 503.01 (Item number: 00193345-01)
Version description 503.01 SP 1 (Item number: 00193297-01)
Version description 503.02 (Item number: 00193345-02)
Version description 503.03 (Item number: 00193345-03)
Version description 503.04 (Item number: 00193345-04)
Version description 504.02 (Item number: 00193706-02)
Version description 504.02 SP1 (Item number: 00194026-01)
Version description 504.02 SP2 (Item number: 00194026-02)
Version description 505.01 (Item number: 00193794-01)
Version description 505.02 (Item number: 00193794-02)
Version description 505.02 SP 1 (Item number: 00193794-03)
Version description 505.02 SP 2 (Item number: 00193794-04)
Version description 505.03 (Item number: 00193794-05)
Version description 505.03 SP1 (Item number: 00193794-06)
Version description 505.04 (Item number: 00193794-08)
Version description 505.04 SP1 (Item number: 00193794-09)
Version description 505.04 SP2 (Item number: 00193794-10)
Corrected defects
Following defects have been fixed in the SC software version 505.05.
Error number Description
1-IHQIS On an HF/3 machine the video multiplexer did not switch the screen between ICOS
and station.
D1-33591607 An HF machine hung up with a NUC error during calibrating in component teaching
mode.
D1-33827113 On an HS60 machine it was not possible to adjust the conveyor width to 110 mm when
the long board stopper was installed. The conveyor minimum width has been changed
in the eSW.
D1-33850220 On an HS50 machine the fine calibration calculated the machine accuracy by 60µm /4
Sigma instead of 90 µm /4 Sigma.
72 of 150

Software Version Description, Station Software 505.05 07/2008 Edition
Error number Description
D1-34886208 Pseudo track empty error. A track empty error message was displayed but the
machine picked up the component from the track concerned. The error message is
now displayed as an common error.
D1-36083327 The main error display was not activated at machine error 3574.
D1-36759801 After registration of a changeover table on an HS50 machine, trays with dual
packaging units were not unlocked, as the infrastructure was overloaded due to a high
amount of message. The architecture has been improved.
D1-36975233 After a program change on an HF/3 machine, the first component inspected by the
coplan laser was always rejected and no error message was displayed on the station
computer. The measuring command was handed over too late.
D1-38290611 After installation of the station software 505.04 SP1 on an HS60 machine, the
Component level indicator showed "0" as original quantity of all components.
D1-39609001 On an HF machine a track empty error occured, as the tape component pocket was
empty. After the track was set to full the transport moved towards the component with
full power. The machine hung up with the error message 19080 "Crash danger!
Segment cannot be transported to a higher position". Teaching is now being
deactivated when vacuum check is off.
D1-40108702 Due to an incorrect message for the DIP switch, it was not possible to download the
firmware for station software 505.04 SP2. The message has been corrected.
D1-40156649 On an S27 HM machine with multicolor cameras the hotfix_2 to 505.04 SP2 did not
work correct. The potential correction of the component pickup position regularly
caused a permanent camera flashlight and it was impossible to quit with the "Esc"
button. The error has been corrected.
D1-40216904 On an HF/3 machine the component level of the packaging unit was lost after
rebooting the station. The process has been optimized.
D1-40637259 Due to a translation error, it seemed to be possible to choose between a 3x8 and a
2x8mm feeder in the fine calibration in som languages. The GUI text has been
corrected for the languages concerned.
D1-40706513 On an HF/3 machine an error message was displayed, that the distances of the PCB
fiducials were beyond the tolerance. The tolerance value was to low in the data base
for the multicolor camera. The tolerance value has been adjusted in the data base.
D1-40767931 After an upgrade from station software 505.03 SP1 to 505.04 SP2 on an HF/3 machine
an internal system error occurred. The error has been corrected.
73 of 150