Software Version Description, Station Software 505.05 07/2008 Edition - Anti-crash circuit in PA1 at the HF (from series A-001): In an HF/3, the anti-crash board applies a 15 V si gnal at an input port in order to query …
Software Version Description, Station Software 505.05 07/2008 Edition
-
Manual tray:
Only for location 2 and location 4.
- Component level indicator:
The display of the boards which can be fit with the current component configuration is only valid,
when the first board of a panel is finished.
- Multiple measurement (MFOV):
If only the outline of a component is described with the SIPLACE Pro programming system, the
position is only measured with the SIZE algorithm. Multiple measurement (MFOV) is not
possible with this algorithm. This can produce the following error on SIPLACE HF machines with
the stationary IC camera (type 22, field of view 40 x 50 mm):
If the size of the component is, for instance, 38 x 45 mm, it can be measured in the
manipulator at a pick-up angle of 0° (no multiple measurement), but not at a pick-up angle of 90°
(multiple measurement necessary). An identical error can occur when placing the component.
The placement angle is the critical issue here.
Remedy: If this error occurs, the component can be described with a row of leads for every
edge. To measure the position, the ROW algorithm must then be used.
- Twin Head nozzle changer:
Since the Twin Head nozzle changer is not an option, the nozzle cannot be changed manually
by acknowledging it.
Reason: The risk resulting from changing nozzles manually is that the nozzles are not seated
correctly. The Twin Head nozzle changer eliminates this risk.
- Number of package forms set 540:up multiplied by the number of configured sensor
systems is restricted to a maximum of
For any given job passed to the station, the number of package forms multiplied by the number
of sensor systems is not permitted to exceed 540.
Example: If 5 sensor systems are configured on the machine, then a maximum of 108 package
forms may be specified (108 x 5 = 540).
78 of 150

Software Version Description, Station Software 505.05 07/2008 Edition
-
Anti-crash circuit in PA1 at the HF (from series A-001):
In an HF/3, the anti-crash board applies a 15 V signal at an input port in order to query the
status of the anti-crash board. For the HF (from series A-001) (SW 505.02), the Logical
Subsystem I/O (LSSIO) has already been taken over from the 601 software. This means that
this port is queried. However, it is not possible to set a port to the status "low" or "high".
Workaround: A connector with a bridge between pin 1 and 4 is installed at connector No. X4 ra
(see fig. below) in the subdistributor of all HF machines (from series A-100). This sets the input
for the gantry distance to "high" at hardware level. Connector X4 ra was previously unused.This
connector is installed for system acceptance purposes and may not be removed.
Note:
This connector is installed for system acceptance purposes and may not be removed. If the
connector is removed, error messages relating to the gantry distance are output. This
connector is not installed at the standard HF and is not required there. Connector X4 ra
therefore continues to be unused in the HF.
Note:
For more details please refer to the technical information "Anti Crash Circuit in PB 1 at the HF
(from series A-001)" (44V01084).
Fig. 6-1: Connector X4 ra in the subdistributor
79 of 150
Software-Versionsbeschreibung Stationssoftware 505.05 Ausgabe 07/2008
80 von 150
1. Kurzbeschreibung
Dieses Dokument beschreibt die Betriebssoftware der SIPLACE
®
-Automaten in Version 505.05 mit
folgenden Komponenten:
- Grafische Bedienoberfläche (GUI)
- Testsoftware (SITEST)
- Stationsrechner (SR)
- Maschinencontroller (MC)
Die Software wurde speziell zum Betrieb der folgenden Automatentypen entwickelt:
- SIPLACE HF
- SIPLACE HF/3
- SIPLACE HS-50, HS-50+
- SIPLACE HS-60
- SIPLACE S-25HM
- SIPLACE S-27HM