SOM-1735-001.pdf - 第20页

(B01-04) Polarity Existence Set "Enable" or "Disable" to determine whether or not the component has a polarity (direction). This data is used for optimization of the pattern program. Select "Enab…

100%1 / 77
(1) X [mm] (Horizontal), Y [mm] (Vertical)
Set Dimensions X and Y of the molded section.
Unit: mm
Area Array
Fig. 28
Data Input Range:
X: 0.01 to 150.00
Y: 0.01 to 150.00
(2) T [mm] (thickness), t [mm] (thickness), and Ut [mm] (thickness)
Set the thickness of the component.
T [mm] (thickness) : Thickness between Component Place-
ment and Uppermost Surfaces
t [mm] (thickness) : Thickness between Component Place-
ment and Nozzle Pickup Surfaces
Ut [mm] (thickness) : Thickness between Component Lower-
most and Placement Surfaces
Unit: mm
Data Input Range: 0 to 9.99
Example of "T = t"
Fig. 30
Fig.27
X [mm] (Horizontal)
Y [mm] (Vertical)
3.30 [mm]
3.30 [mm]
0307-001 18 Tg0930-PM-SO
Note
5.2 Parameters (B01-02)
5.70 [mm]
5.70 [mm]
0.00 [mm]
T [mm] (thickness)
t [mm] (thickness)
Ut [mm] (thickness)
Fig.29
(B01-04) Polarity Existence
Set "Enable" or "Disable" to determine whether or not the component
has a polarity (direction).
This data is used for optimization of the pattern program.
Select "Enable" or "Disable".
Refer to the instruction manual "Optimization Software" for de-
tails.
(B01-11) Electrical Contact Data
Set the basic parameters related to the electrodes of the components.
Fig. 32
(1) Grid Type
Select one of the following grid types.
Regular : Regular Lattice
Custom : Lattice having no electrodes at 4 corners
Checker : Staggered Array
Reversed Checker : Reversed Staggered Array
Fig. 34
(2) Image
Select one of the following options depending on how the image of
the electrode is captured in comparison with the mold.
Bright : Select this when the captured image looks brighter than
the mold.
Dark : Select this when the captured image looks darker than
the mold.
(a) In normal cases, select "Bright".
(b) When the mold of a BGA component is made of ceramic, it might be
better to select "Dark".
Fig.35
Image Bright
Fig.33
Grid Type Regular
5.2 Parameters (B01-04), (B01-11)
Fig.31
Polarity Existence
Enable
Note
Note
0307-001 19 Tg0930-PM-SO
(3) # Of types
Set the number of electrode types.
Data Input Range: 1 to 3
When several types are specified, it becomes possible to handle such
components that have electrodes of different diameters.
(4) # Of groups
Set the number of electrode groups.
Data Input Range: 1 to 6
When the formation of a special BGA cannot be expressed by a certain
array type, such a BGA component can be used by increasing the num-
ber of electrode groups.
Groups can be overlapped with each other.
Example: The electrodes arrayed in the 1st and 6th rows are shifted
by half a pitch, compared with the electrodes in the 2nd
through 5th rows.
Fig. 38
(5) Extended setting
Select "Enable" or "Disable" to determine whether or not the extended
data should be used.
When "Enable" is set in the "Extended setting" text box, the extended
data such as information on missing electrodes can be specified.
The following shows the extended data that can be specified.
Table 9
Area Array
BGA/CSP
# of Types
# of Groups
Missing Elctd Set
Fig.36
# Of types
1
Fig.37
# Of groups
1
5.2 Parameters (B01-11)
Note
Note
Fig.39
Extended setting Enable
0307-001 20 Tg0930-PM-SO