SOM-1735-001.pdf - 第34页
• In the case of "BGA", the center of the ball grids must be aligned with the center of the mold. Fig. 76 Sequence of Polarity Determination T op View of Component (Polarity Different by 180°) Fig. 77 0307-001 …

0307-001 32 Tg0930-PM-SO
(B02-14) Polarity detn
Specify how to determine the polarity (direction) of the component.
Fig. 74 Edit Window (Example)
(1) Polarity detn
Set a parameter to specify whether or not the polarity determination
should be made.
Disable : Select this when the polarity determination
should not be made.
Enable (Discard) : When the polarity is checked and determined
as a different one, a recognition error occurs.
Enable (Placement) : After the polarity is checked and determined,
the component is placed according to the de-
termined polarity.
(a) When "Enable (Placement)" is selected, the recognition processing
time becomes twice or more as long as the normal one.
(b) When it is required to check whether or not a component has a po-
larity (when components are not fed in the specified direction), "En-
able (Discard)" or "Enable (Placement)" must be set in the text box.
The machine performs the recognition operation after checking the
polarity.
(c) The following requirements must be met when "Enable (Discard)" or
"Enable (Placement)" is selected.
• The average gray value in the inspection range of the polarity
mark must be 20 shades of gray or more, compared with the other
inspection ranges.
(The gray value in the inspection range can be checked through
the component recognition test.)
5.2 Parameters (B02-14)
Fig.75
Polarity detn
Disable
Note

• In the case of "BGA", the center of the ball grids must be aligned
with the center of the mold.
Fig. 76
Sequence of Polarity Determination
Top View of Component
(Polarity Different by 180°)
Fig. 77
0307-001 33 Tg0930-PM-SO
5.2 Parameters (B02-14)

5.2 Parameters (B02-14)
Fig.78
Inspection method 4-Point Insp
0307-001 34 Tg0930-PM-SO
(2) Inspection method
Specify how many places should be inspected for polarity determina-
tion.
Select "4-Point Insp" or "2-Point Insp" as an inspection method.
4-Point Insp: Select this to inspect the four places rotated in incre-
ments of 90°, based on the center of the component.
Select this for a square component.
Fig. 79
2-Point Insp: Select this to inspect the two places rotated by 180°,
based on the center of the component.
Select this for a rectangular component.