SOM-1735-001.pdf - 第62页

Recognition Error ID Item Description 02 ** 3601 ** Error in Electrode(ball) Detection. No Electrode (ball) Detected. 02 ** 3602 ** Error in Electrode(ball) Detection. Since a sufficient number of Electrode (ball) were u…

100%1 / 77
Recognition Error ID Item Description
02 ** 2301 ** Error in Electrode(Ball) Inspection The Electrode(ball) position is incorrect.
02 ** 2302 ** Error in Electrode(Ball) Inspection There is Electrode (ball) of the size out-
side permissible value.
(Cause 1) The component is different from the specified one.
(Cause 2) A component is defective.
(Cause 3) Wrong Data
(Remedy 1) Check the component.
(Remedy 2) Check the component.
(Remedy 3) Refer to "5.2 Parameters" and set correct ones.
02 ** 2401 ** Error in Polarity Detection. Failed in Polarity Detection.
02 ** 2402 ** Error in Polarity Detection. The detected polarity differs from specifi-
cation.
(Cause 1) The polarity data is wrong.
(Cause 2) A good image of the polarity mark is not captured.
(Cause 3) The direction of the component is wrong.
(Remedy 1) Refer to "5.2 Parameters" and set correct ones.
(Remedy 2) Check how the image of the component is captured.
When good images of the polarity marks on several components are
not captured, stable inspections cannot be made. In this case, set "Dis-
able" in the "Polarity detn" text box.
(Remedy 3) Check the component.
02 ** 2901 ** Picked Posture Error The pick angular skew is big.
02 ** 2902 ** Picked Posture Error The pick-up position has deviated greatly
in X direction.
02 ** 2903 ** Picked Posture Error The pick-up position has deviated greatly
in Y direction.
02 ** 2904 ** Picked Posture Error The pick-up position has deviated greatly
in X or Y direction.
(Cause 1) When a component is picked up, the pick-up positions (X and Y) and
angle have shifted greatly from the correct ones.
(Cause 2) When the tape is fed, a component is turned vertically.
(Remedy 1) Check the selected component and the tape feeder.
Check if the feeder (B) offset data is correct.
Check if the component library data is correct.
(Remedy 2) Check the selected component and the tape feeder.
0307-001 60 Tg0930-PM-SO
10.4 Recognition Error IDs and Remedial Procedures
Recognition Error ID Item Description
02 ** 3601 ** Error in Electrode(ball) Detection. No Electrode (ball) Detected.
02 ** 3602 ** Error in Electrode(ball) Detection. Since a sufficient number of Electrode (ball)
were undetectable, it cannot position.
02 ** 3603 ** Error in Electrode(ball) Detection. There is Electrode (ball) undetectable in
the line or sequence of a group outside.
02 ** 3604 ** Error in Electrode(ball) Detection. Electrode (ball) which is in agreement with
data was undetectable.
02 ** 3605 ** Error in Electrode(ball) Detection. Electrode (ball) which is not specified was
detected.
(Cause 1) A component is defective.
(Cause 2) The component is different from the specified one
(Cause 3) Wrong Data
(Cause 4) When a component is picked up, the pick-up positions (X and Y) and
angle have shifted greatly from the correct ones.
(Remedy 1) Check the component.
(Remedy 2) Check the component.
(Remedy 3) Refer to "5.2 Parameters" and set correct ones.
(Remedy 4) Check the selected component and the tape feeder.
Check if the feeder (B) offset data is correct.
Check if the component library data is correct.
02 ** 8001 ** Data Error Data Error in Process.
02 ** 8002 ** Data Error Error in Lighting Data.
(Cause 1) Self-Diagnostics Error Message.
(Remedy 1) Contact our service personnel for details.
02 ** 9001 ** Other Errors Internal Processing Error.
02 ** 9002 ** Other Errors Impossible to set the detection window.
02 ** 9003 ** Other Errors Impossible to set the window for arrayed
lead end detection.
02 ** 9004 ** Other Errors Impossible to set the window for lead de-
tection at the corner.
02 ** 9005 ** Other Errors Impossible to set the window for lead de-
tection.
02 ** 9006 ** Other Errors Angle Calculation Impossible.
02 ** 9007 ** Other Errors Internal Processing Error.
(Cause 1) Self-Diagnostics Error Message.
(Remedy 1) Contact our service personnel for details.
0307-001 61 Tg0930-PM-SO
10.4 Recognition Error IDs and Remedial Procedures
(3) Various Teaching Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (Only 0)
Primary Error Classification (0 to 5)
Classification of Recognition Functions (10)
(a) Error IDs "*" will be filled with detail codes.
(b) When an error ID other than the described ones is issued,
contact our service personnel for some advice.
Table 21
Recognition Error ID Item Description
10 03 0 14001 ---- Error in Lighting Intensity Data (Front
Lighting 3)!
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one. Or, contact our service personnel for
some advice.
10 03 0 14002 ---- Error in Lighting System (Front Lighting 3)!
Failed in Teaching Operation for Assumed
Brightness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
Note
0307-001 62 Tg0930-PM-SO
10.4 Recognition Error IDs and Remedial Procedures