SOM-1735-001.pdf - 第58页

Recognition Error ID Item Description 01 39 2 14008 "Elctd T ype No." in "Elctd Group 6" is improper . 01 39 2 14009 "Elctd Row or Col Pitch" in "Elctd Group 1" is larger than “Elc…

100%1 / 77
10.4 Recognition Error IDs and Remedial Procedures
(1) Recognition Communication Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification
Only at Primary Classification Communica-
tion Command
1 : Data Range Error
2 : Data Combination Error
Primary Error Classification
10 to 70: Communication Commands
90 : Communication Procedure
91 : Command Error
92 : Response Error
Classification of Recognition Functions (01)
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 18
Recognition Error ID Item Description
01 ** 1 ***** Error in Recognition Communication
Data.
(Cause) An error was found in the recognition communication data.
(Remedy 1) Contact our service personnel for details.
01 39 2 14001 "# of Types" (elctd data) is improper.
01 39 2 14002 "# of Groups" (elctd data) is improper.
01 39 2 14003 "Elctd Type No." in "Elctd Group 1" is
improper.
01 39 2 14004 "Elctd Type No." in "Elctd Group 2" is
improper.
01 39 2 14005 "Elctd Type No." in "Elctd Group 3" is
improper.
01 39 2 14006 "Elctd Type No." in “Elctd Group 4" is
improper.
01 39 2 14007 "Elctd Type No." in "Elctd Group 5" is
improper.
10.4 Recognition Error IDs and Remedial Procedures
Note
0307-001 56 Tg0930-PM-SO
Recognition Error ID Item Description
01 39 2 14008 "Elctd Type No." in "Elctd Group 6" is
improper.
01 39 2 14009 "Elctd Row or Col Pitch" in "Elctd Group
1" is larger than “Elctd Dim”.
01 39 2 14010 "Elctd Row or Col Pitch" in "Elctd Group
2" is larger than "Elctd Dim".
01 39 2 14011 "Elctd Row or Col Pitch" in "Elctd Group
3" is larger than "Elctd Dim".
01 39 2 14012 "Elctd Row or Col Pitch" in "Elctd Group
4" is larger than "Elctd Dim".
01 39 2 14013 "Elctd Row or Col Pitch" in "Elctd Group
5" is larger than "Elctd Dim".
01 39 2 14014 "Elctd Row or Col Pitch" in "Elctd Group
6" is larger than "Elctd Dim".
01 39 2 14015 "Missing Start Row or Col" in "Elctd
Group 1" is too large.
01 39 2 14016 "Missing Start Row or Col" in "Elctd
Group 2" is too large.
01 39 2 14017 “Missing Start Row or Col” in “Elctd
Group 3" is too large.
01 39 2 14018 "Missing Start Row or Col" in "Elctd
Group 4" is too large.
01 39 2 14019 "Missing Start Row or Col" in "Elctd
Group 5" is too large.
01 39 2 14020 "Missing Start Row or Col" in "Elctd
Group 6" is too large.
01 39 2 14021 “Polarity Inspection Position” Out of
“Mold Size”
01 39 2 14022 “Elctd # of Rows or # of Cols” in “Elctd
Group 1" is Not Sufficient
01 39 2 14023 "Elctd # of Rows or # of Cols" in "Elctd
Group 2" is Not Sufficient
01 39 2 14024 “Elctd # of Rows or # of Cols” in “Elctd
Group 3" is Not Sufficient
01 39 2 14025 “Elctd # of Rows or # of Cols” in “Elctd
Group 4" is Not Sufficient
01 39 2 14026 "Elctd # of Rows or # of Cols" in "Elctd
Group 5" is Not Sufficient
01 39 2 14027 "Elctd # of Rows or # of Cols" in "Elctd
Group 6" is Not Sufficient
01 39 2 14028 Electrode Position Superposed in
Different Electrode Group!
01 39 2 21003 Failed in Automatic Selection of
Algorithm for Area Array.
01 39 2 21010 Failed in Automatic Selection of
Algorithm for BGA Components.
01 39 3 14101 Error in "Component Library Elctd Type
No" Data.
0307-001 57 Tg0930-PM-SO
10.4 Recognition Error IDs and Remedial Procedures
Recognition Error ID Item Description
01 39 3 14111 "Component Library Elctd Shape" Not
Supported!
01 39 3 14112 Error in "Component Library Elctd Dim1"
Data.
01 39 3 14113 Error in "Component Library Elctd Dim2"
Data.
01 39 3 14213 Error in "Component Library Elctd Gp
Posn X or Y" Data.
01 39 3 14214 Error in "Component Library Elctd Col
Pitch" Data.
01 39 3 14215 Error in "Component Library Row Pitch"
Data.
01 39 3 14216 Error in "Component Library Elctd # of
Cols" Data.
01 39 3 14217 Error in "Component Library Elctd # of
Rows" Data.
01 39 3 14221 Error in "Component Library Elctd Missing
Elctd No" Data.
01 39 3 14231 Error in "Component Library Elctd Missing
Std Col" Data.
01 39 3 14232 Error in "Component Library Elctd Missing
Std Row" Data.
01 39 3 14233 Error in "Component Library Elctd # of
Missing Cols" Data.
01 39 3 14234 Error in "Component Library Elctd # of
Missing Rows" Data.
01 39 3 22001 "Component Library Polarity detn" Not
Supported!
01 39 3 22002 "Component Library Polarity Inspection
method" Not Supported!
01 39 3 22003 "Component Library Polarity Detn
Inspection Pos X or Y" Not Supported!
01 39 3 22004 "Component Library Polarity Detn
Inspection range" Not Supported!
01 39 3 26101 "Component Library Electd Pos detn"
Not Supported!
01 39 3 26102 Error in “Component Library Electd Pos
tol” Data.
01 39 3 26201 "Component Library Electd Size detn"
Not Supported!
01 39 3 26202 Error in "Component Library Electd Size
tol" Data.
(Cause) Each data of the component library is wrong.
(Remedy 1) Refer to "5.2 Parameters" and set correct ones.
0307-001 58 Tg0930-PM-SO
10.4 Recognition Error IDs and Remedial Procedures