SOM-1735-001.pdf - 第32页

(2) Electd pos tol [mm] Set the tolerance value for the electrode position. Unit: mm Dat a Input Range: 0 to 9.999 T o specify a parameter , "Manual" must be set in the "Recog data set" text box and &…

100%1 / 77
(B02-06) View Range Set
Set a view size to be used for recognition.
Select one of the following options.
Auto Selection Small View Large View
Auto Selection : "Large View" or "Small View" can be selected
automatically according to the selected com-
ponent.
Small View : Select this to use the small view (movable cam-
era).
Large View : Select this to use the large view (fixed cam-
era).
In normal cases, select "Auto Selection".
To set a parameter, select "Manual" in the "Recog data set" text box.
(B02-13) Electrode Recognition Data
(1) Electrode Position Determination
Select an option to specify whether or not the electrode position should
be determined.
Select one of the following options.
Disable Enable (Auto) Enable (Mnl)
Disable : Select this when the electrode position determi-
nation should not be made.
Enable (Auto) : Select this to make the electrode position deter-
mination.
The automatically specified default is used as an
electrode position tolerance.
Enable (Mnl) : Select this to make the electrode position deter-
mination.
The arbitrarily specified value is used as an elec-
trode position tolerance.
To set a parameter, select "Manual" in the "Recog data set" text
box.
5.2 Parameters (B02-06), (B02-013)
Fig.71
Auto Selection
View Range Set
Note
Note
0307-001 30 Tg0930-PM-SO
Electd pos tol [mm]
0.000
Enable (Auto)
Elctd pos detn
Fig.72
(2) Electd pos tol [mm]
Set the tolerance value for the electrode position.
Unit: mm
Data Input Range: 0 to 9.999
To specify a parameter, "Manual" must be set in the "Recog
data set" text box and "Enable (Mnl)" in the "Elctd pos detn" text
box (described in (1)).
(3) Electd size detn
Select an option to specify whether or not the electrode size should
be determined.
Select one of the following options.
Disable Enable (Auto) Enable (Mnl)
Disable : Select this when the electrode size determination
should not be made.
Enable (Auto) : Select this to make the electrode size determina-
tion.
The automatically specified default is used as an
electrode size tolerance.
Enable (Mnl) : Select this to make the electrode size determina-
tion.
The arbitrarily specified value is used as an elec-
trode size tolerance.
To set a parameter, select "Manual" in the "Recog data set" text box.
(4) Electd size tol [mm]
Set the tolerance value for the electrode size.
Unit: mm
Data Input Range: 0 to 9.999
To specify a parameter, "Manual" must be set in the "Recog
data set" text box and "Enable (Mnl)" in the "Elctd size detn"
text box (described in (1)).
Note
Electd size tol [mm]
0.000
Enable (Auto)
Electd size detn
Fig.73
Note
0307-001 31 Tg0930-PM-SO
5.2 Parameters (B02-13)
Note
0307-001 32 Tg0930-PM-SO
(B02-14) Polarity detn
Specify how to determine the polarity (direction) of the component.
Fig. 74 Edit Window (Example)
(1) Polarity detn
Set a parameter to specify whether or not the polarity determination
should be made.
Disable : Select this when the polarity determination
should not be made.
Enable (Discard) : When the polarity is checked and determined
as a different one, a recognition error occurs.
Enable (Placement) : After the polarity is checked and determined,
the component is placed according to the de-
termined polarity.
(a) When "Enable (Placement)" is selected, the recognition processing
time becomes twice or more as long as the normal one.
(b) When it is required to check whether or not a component has a po-
larity (when components are not fed in the specified direction), "En-
able (Discard)" or "Enable (Placement)" must be set in the text box.
The machine performs the recognition operation after checking the
polarity.
(c) The following requirements must be met when "Enable (Discard)" or
"Enable (Placement)" is selected.
The average gray value in the inspection range of the polarity
mark must be 20 shades of gray or more, compared with the other
inspection ranges.
(The gray value in the inspection range can be checked through
the component recognition test.)
5.2 Parameters (B02-14)
Fig.75
Polarity detn
Disable
Note