DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第100页
1-78 Advanced Chip Shooter DECAN S2 T roubleshooting Guide The PCB that moved out of the detection range of the placement se nsor was not detected b y the workout sensor within a certain period of time. [Solution] T …

1-77
System Messages of the MMI and Solutions
When a PCB has dropped due to the excessive width of conveyor, reduce the width,
remove the dropped PCB, and start again.
Widen the conveyor width when a PCB got jammed due to narrow conveyor width.
Check if the belt of the corresponding station operates normally.
If there is any mechanical interference that obstructs the flow of the corresponding
PCB, remove it.
Check the operation status of the corresponding PCB. If it has a problem, replace it.
If any problem occurs, contact the C/S company designated by Hanwha Precision
Machinery Co., Ltd. or the local agent.
Warning Adjusting the sensor or correcting an error while the
equipment is ready could result in personal injury. Be sure
to adjust the sensor or correct an error in the stop status
(idle mode) after canceling the ready status.
$3092 The board did not get out of the detection range of the inlet sensor.. [EMER LEVEL]
[Problem]
The PCB detected by the inlet sensor is stuck.
[Solution]
Take measures same as those against the error code "$3091”.
$3093 The board did not arrive at the placement sensor. [EMER LEVEL]
[Problem]
The PCB that moved out of the detection range of the inlet sensor is stuck.
[Solution]
Take measures same as those against the error code “$3091”.
$3094 The board did not get out of the detection range of the placement sensor. [EMER
LEVEL]
[Problem]
The PCB detected by the placement sensor is stuck.
[Solution]
Take measures same as those against the error code “$3091”.
$3095 The board did not arrive at the WorkOut sensor.. [EMER LEVEL]
[Problem]

1-78
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
The PCB that moved out of the detection range of the placement sensor was not
detected by the workout sensor within a certain period of time.
[Solution]
Take measures same as those against the error code “$3091”.
$3096 The board did not move out of the detection range of the WorkOut sensor. [EMER
LEVEL]
[Problem]
The PCB failed to be moved to the exit shuttle after it was detected by the WorkOut
sensor.
[Solution]
Take measures same as those against the error code “$3091”.
$3097 The board did not arrive at the BoardOut sensor. [EMER LEVEL]
[Problem]
The PCB that moved out of the detection range of the WorkOut sensor did not arrive at
the BoardOut sensor.
[Solution]
Take measures same as those against the error code “$3091”.
$3098 The board did not move out of the detection range of the BoardOut sensor. [EMER
LEVEL]
[Problem]
The board did not move out of the detection range of the BoardOut sensor.
[Solution]
Take measures same as those against the error code “$3091”.
Check if the BoardOut sensor is at the same height as the conveyor of the next
machine.
$3099 The board did not arrive at the stopper. [EMER LEVEL]
[Problem]
The PCB did not arrive at the stopper in the corresponding station.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Check if there is any mechanical interference that obstructs the flow of the
corresponding PCB.
Check if the belt of the corresponding station operates normally

1-79
System Messages of the MMI and Solutions
1.4.5. Sequence related errors [$4000~$4fff]
$4000 Components that can't be operated together exist in a cycle. [EMER LEVEL]
[Problem]
The components that can't be operated together exist in a cycle.
Occurs when applying undefined component alignment method or when the camera
number is designated.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
If the type of the error is “MPU-STOP”, then turn on/off the power switch of the
equipment.
Reset the alignment type of the component in trouble and the camera number.
Divide one cycle into two and operate.
$4003 The camera cannot recognize a part. [FREEZE LEVEL]
[Problem]
An attempt was made to recognize a part with a camera that cannot recognize a part
(for example, an attempt was made to recognize a part using a fiducial camera)
[Solution]
Recognize a part using a fly or fix camera.
$4116 Since the pneumatic system for the head$H is turned on already, the part cannot be
picked up. [EMER LEVEL]
[Problem]
Since the pneumatic system for the corresponding head is turned on, the part cannot be
picked up.
[Solution]
If the pneumatic system for the corresponding head has been manually turned on, turn
it off and retry.
If it was neglected to dump the previously picked up part, remove the part at the
corresponding head, turn it off and then retry.
If it was neglected to dump the previously picked up part, remove the part at the
corresponding head, turn it off and then retry.
$4120 The dump box was not defined. [EMER LEVEL]
[Problem]
The dump box into which the picked up part by the designated head is to be dumped
was not designated.