DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第148页
1-126 Advanced Chip Shooter DECAN S2 T roubleshooting Guide [Solution] Perform [Sol ution[Solution]] in $a635. $a641 There is a bright pixel outside the first( left side) lead of upper lead group. [Problem] The lead …

1-125
System Messages of the MMI and Solutions
The foreign matter is recognized as lead.
The component size was inputted incorrectly.
[Solution]
Check if the component is actually picked up.
If there is any foreign matter between nozzle and mirror or between leads, please
remove it. For the method to remove foreign matter from the nozzle, please refer to “
Checking and cleaning the nozzle” in the “Maintenance Handbook”.
Perform [Solution] in $a610.
$a636 There isn’t boundary at the first(upper side)lead of left lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
The foreign matter is recognized as lead .
The component size was inputted incorrectly.
[Solution]
Perform [Solution] in $a635.
$a637 There isn’t boundary(%d) at the first(left side)lead of lower lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
The foreign matter is recognized as lead.
The component size was inputted incorrectly.
[Solution]
Perform [Solution] in $a635.
$a638 There isn’t boundary(%d) at the first(upper side)lead of right lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
The foreign matter is recognized as lead.
The component size was inputted incorrectly.

1-126
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
[Solution]
Perform [Solution[Solution]] in $a635.
$a641 There is a bright pixel outside the first(left side) lead of upper lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
The nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a642 There is bright pixel at the first(upper side) lead of left lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
The nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a643 There is bright pixel outside of the first(left side) lead of lower lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
he nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635..
$a644 There is bright pixel outside of the first(left side) lead of lower lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.

1-127
System Messages of the MMI and Solutions
The mirror is contaminated with foreign matter.
he nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a645 Boundary at the first(left side) lead of upper lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is actually defective.
False recognition of foreign matter as lead.
The component data and lighting setup is inadequate.
[Solution]
The component data and lighting setup is inadequate.
Perform [Solution] in $a635.
$a646 Boundary at the first(upper side) lead of left side lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is defective.
False recognition of foreign matter as lead.
False recognition of foreign matter as lead.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.
$a647 Boundary at the first(left side) lead of the lower lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of component is defective.
False recognition of foreign matter as lead.
Component data and lighting setup is inadequate.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.