1-134 Advanced Chip Shooter DECAN S2 T roubleshooting Guide  Rotated too much during pickup of the component. [Solution]  Check through SMV ision window to determine the pickup positio n of the corresponding compon ent…

100%1 / 200
1-133
System Messages of the MMI and Solutions
Occurs when there is big difference between the recognized component width and
registered value.
Defective component.
The component data and lighting setup is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a823 Height of the component(Y value) does not match with the registered value.
[Problem]
Occurs when there is big difference between the recognized component width and
registered value.
Defective component.
The component data and lighting setup is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a824 Center of the component is deviating too much from the nozzle center in X direction.
[Problem]
The component is recognized, but it is too much offset.
Pickup position or pickup condition of the component is inadequate.
[Solution]
Check through SMVision window to determine the pickup position of the
corresponding component in the Feeder of the “PCB Edit” menu.
$a825 Center of the component is deviating too much from the nozzle center in X direction.
[Problem]
The component is recognized, but it is too much offset.
Pickup position or pickup condition of the component is inadequate.
[Solution]
Check through SMVision window to determine the pickup position of the
corresponding component in the Feeder of the “PCB Edit” menu.
$a826 Angle of the component is too wide.
[Problem]
Recognized angle of the component exceeds the registered range.
1-134
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Rotated too much during pickup of the component.
[Solution]
Check through SMVision window to determine the pickup position of the
corresponding component in the Feeder of the “PCB Edit” menu.
$a830 No object is visible in the retrieve range.
[Problem]
The component was not actually picked up.
Lighting is too dark.
[Solution]
Check if the component has actually picked up.
Select the error occurred component in “Part” of the “PCB Edit” menu and check the
illumination setup in the Profile Editor. Please refer to the [Solution] in $a610.
$a831 Background of image is too bright.
[Problem]
Lighting is set up too bright.
Foreign matter other than the component is recognized in the vision.
[Solution]
Perform [Solution] in $a635.
$a832 The component looks too dark.
[Problem]
$a832The component looks too dark.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and check the
illumination setup in the Profile Editor. Please refer to the [Solution] in $a610.
$a833 Can not find the boundary line of the component.
[Problem]
$a833Can not find the boundary line of the component.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and check the
illumination setup in the Profile Editor. Please refer to the [Solution] in $a610.
$a842 Failed in retrieving the first pin between the pins at both ends of lead group.
[Problem]
1-135
System Messages of the MMI and Solutions
Failed in detailed recognition of lead.
The component lead is defective.
Lighting setup of the component data is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a843 Failed in retrieving the last pin between the pins at both ends of lead group.
[Problem]
Failed in detailed recognition of lead.
The component lead is defective.
Lighting setup of the component data is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a844 Number of pins of recognized lead group is too few.(Less than 4)
[Problem]
Number of recognized pins is too few(Less than 4).
The component lead is defective.
The component data and lighting setup is inadequate.
[Solution]
Register the components with less than 4 leads as Tr.
Check if the component is actually defective.
Perform [Solution] in $a610.
$a845 There isn’t a pin which should be in the lead group.
[Problem]
Numbers of recognized lead registered lead are different.
The component lead is defective.
The component data or lighting setup is inadequate.
[Solution]
Register the components with less than 4 leads as Tr.
Check if the component is actually defective.
Perform [Solution] in $a610.