DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第165页

1-143 System Messages of the MMI and Solutions  The tolerance H of t he component was set up too small.  The nozzle is co ntaminated with foreign matter . [Solution]  Check if the compon ent was correctly picked up. …

100%1 / 200
1-142
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Incorrect input of the ‘Body X’of the component.
The tolerance L of the component was set up too small.
The nozzle is contaminated with foreign matter..
[Solution]
Check on the ‘PCB Edit Part’ of the MMI if ‘Body X’ of the component is correctly
input.
On the ‘PCB Edit Part’ of the MMI input the tolerance L of the component as 30%.
Remove foreign matter from the nozzle, if any.
Please refer to the [Solution] in $a635.
$aa1a Length of the component was recognized larger.
[Problem]
Incorrect input of the ‘Body X’ of the component.
The tolerance L of the component was set up too large.
The nozzle is contaminated with foreign matter.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, and check if
the ‘Body X’ at ‘Profile Editor’ has been correctly input.
Select the error occurred component in “Part” of the “PCB Edit” menu, and enter 30%
as the tolerance H in the ‘Profile Editor’.
Remove foreign matter from the nozzle, if any.
Please refer to the [Solution] in $a635.
$aa1b Center of the component is too much offset.
$aa1c Center of the component is deviating too much.
[Problem]
The component is too much offset from the center of nozzle when picking up the
component.
The fly camera shakes during component mounting.
[Solution]
Perform [Solution] in $aa0a.
$aa1d Width of the component is larger than reference value.
[Problem]
The component was not picked up actually.
Incorrect input of the ‘Body X’ of the component.
1-143
System Messages of the MMI and Solutions
The tolerance H of the component was set up too small.
The nozzle is contaminated with foreign matter.
[Solution]
Check if the component was correctly picked up.
Select the error occurred component in “Part” of the “PCB Edit” menu, and check if
the ‘Body X’ at ‘Profile Editor’ has been correctly input.
Select the error occurred component in “Part” of the “PCB Edit” menu, and enter 30%
as the tolerance H in the ‘Profile Editor’.
Remove foreign matter from the nozzle, if any.
Please refer to the [Solution] in $a635.
$aa1e Width of the component is less than reference value.
[Problem]
The component was not picked up.
Incorrect input of the ‘Body X’ of the component.
Too low setup of tolerance L of the component.
The nozzle is contaminated with foreign matter.
[Solution]
Check if the component was correctly picked up.
Select the error occurred component in “Part” of the “PCB Edit” menu, and check if
the ‘Body X’ at ‘Profile Editor’ has been correctly input.
Select the error occurred component in “Part” of the “PCB Edit” menu, and enter 30%
as the tolerance L in the ‘Profile Editor’.
Remove foreign matter from the nozzle, if any.
Please refer to the [Solution] in $a635.
$aa1f Did not pickup the component.
[Problem]
The component was not picked up.
[Solution]
Check if the component is remaining in the corresponding feeder.
If the component is remaining in the corresponding feeder, readjust the pickup
position. Check the pickup position of the corresponding component through the
VisFrame window in “Feeder” of the “PCB Edit” menu.
$aa21 There is a problem with threshold. Set the value higher manually.
[Problem]
1-144
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
The threshold value is too low.
The nozzle is severely damaged.
[Solution]
Increase the threshold value on the ‘PCB Edit Part’ of the MMI or check the status of
nozzle.
Please refer to the [Solution] in $a635.
$aa22 There is a problem with threshold. Set the value higher manually.
[Problem]
The threshold value is too low.
The nozzle is severely damaged.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and increase
the threshold value or check the nozzle state in the “Profile Editor”.
Please refer to the [Solution] in $a635.
$ab00 Incorrect angle has been transmitted from the VME.
[Problem]
When incorrect angle has been transmitted from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab01 Incorrect algorithm number has been transmitted from the VME.
[Problem]
An incorrect algorithm method has been transmitted from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab02 In the case of checking the heat, the number of lower lead shall be more than two.
[Problem]
In the case of checking the heat, the number of lower lead is one, although it shall be
two.
[Solution]
When the lower lead is in one piece, select the error occurred component in “Part” of
the “PCB Edit” menu, and release if “Heat” is ticked on the ‘Align Data’ of the
“Profile Editor”.